• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3110F.2.2 Electrical and Hydraulic Power Systems

Los Angeles Building Code > 31F [SLC] Marine Oil Terminals > 3110F Mechanical and Electrical Equipment > 3110F.2 Marine Loading Arms > 3110F.2.2 Electrical and Hydraulic Power Systems
JUMP TO FULL CODE CHAPTER

3110F.2.2.1 Pressure and Control Systems (N)

  1. Pressure gauges shall be mounted in accordance with ASME B40.100 [10.6].
  2. The hydraulic drive cylinders shall be mounted and meet either the mounting requirements of NFPA T3.6.7 R3 [10.7] or equivalent.
  3. In high velocity current (>1.5 knots) areas, all new marine loading arms shall be fitted with quick disconnect couplers and emergency quick release systems in conformance with Sections 6.0 and 7.0 of [10.3]. In complying with this requirement, attention shall be paid to the commentary and guidelines in Part III of reference [10.3].
  4. Out-of-limit, balance and the approach of out-of-limit alarms shall be located at or near the loading arm console.

3110F.2.2.2 Electrical Components (N)

The following criteria shall be implemented:

  1. Equipment shall be provided with a safety disconnecting device to isolate the entire electrical system from the electrical mains in accordance with Article 430 of the California Electrical Code [10.8].
  2. Motor controllers and 3-pole motor overload protection shall be installed and sized in accor dance with Article 430 of the California Electrical Code [10.8].
  3. Control circuits shall be limited to 120 volts and shall comply with Articles 500 and 501 of the California Electrical Code [10.8]. Alternatively, intrinsically safe wiring and controls may be provided in accordance with Article 504 of the California Electrical Code [10.8] and UL Std. No. 913 [10.9].
  4. Grounding and bonding shall comply with the requirements of Article 430 of the California Electrical Code [10.8] and Section 3111F.

Section 3111F includes requirements for electrical equipment, wiring, cables, controls and electrical auxiliaries located in hazardous areas.

3110F.2.2.3 Remote Operation

The remote control system, where provided, shall conform to the recommendations of the OCIMF [10.3]. The remote operation shall be facilitated by either a pendant control system or by a hand-held radio controller (N).

The pendant control system shall be equipped with a plug-in capability to an active connector located either in the vicinity of the loading arms, or at the loading arm outboard end on the triple swivel, and hard-wired into the control console. The umbilical cord running from the triple swivel to the control console shall be attached to the loading arm. Other umbilical cords shall have sufficient length to reach the maximum operational limits (N).

The radio controller if installed shall comply with 2 CCR 2370 [10.4] and 47 CFR Part 15 [10.10] requirements for transmitters operating in an industrial environment (N/E).

Related Code Sections


3110F.2.2 [SLC] Marine Oil Terminals, Electrical and Hydraulic Power Systems
electrical system from the electrical mains in accordance with Article 430 of the California Electrical Code [10.8]. Motor controllers and 3-pole ...
Los Angeles Building Code > 31F [SLC] Marine Oil Terminals > 3110F Mechanical and Electrical Equipment > 3110F.2 Marine Loading Arms > 3110F.2.2 Electrical and Hydraulic Power Systems
3008.8 Elevators and Conveying Systems, Electrical Power
hours or shall be protected by a listed electrical circuit protective system having a fire-resistance rating of not less than 2 hours. Exception ...
Los Angeles Building Code > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.8 Electrical Power
3008.8 Elevators and Conveying Systems, Electrical Power
protective systems shall have a fire-resistance rating of not less than 2 hours. Electrical circuit protective systems shall be installed in accordance ...
Los Angeles Building Code > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.8 Electrical Power
3007.8 Elevators and Conveying Systems, Electrical Power
hours or shall be protected by a listed electrical protective system having a fire-resistance rating of not less than 2 hours. Exception: Wiring ...
Los Angeles Building Code > 30 Elevators and Conveying Systems > 3007 Fire Service Access Elevator > 3007.8 Electrical Power
3007.8 Elevators and Conveying Systems, Electrical Power
a fire-resistance rating of not less than 2 hours. Electrical circuit protective systems shall have a fire-resistance rating of not less than 2 hours ...
Los Angeles Building Code > 30 Elevators and Conveying Systems > 3007 Fire Service Access Elevator > 3007.8 Electrical Power
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE