• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

803.2.5 Elbow Reduction

Los Angeles Mechanical Code > 8 Chimneys and Vents > 803.0 Sizing of Category Venting Systems > 803.2 Multiple Appliance Vent Table 803.2(1) Through Table 803.2(9) > 803.2.5 Elbow Reduction
JUMP TO FULL CODE CHAPTER
For each elbow up to and including 45 degrees (0.79 rad) in the common vent, the maximum common vent capacity listed in the venting tables shall be reduced by 5 percent. For each elbow exceeding 45 degrees (0.79 rad) up to and including 90 degrees (1.57 rad), the maximum common vent capacity listed in the venting tables shall be reduced by 10 percent. [NFPA 54:13.2.6]

Related Code Sections


510.2.5 Water Heaters, Elbow Reduction
For each elbow up to and including 45 degrees (0.79 rad) in the common vent, the maximum common vent capacity listed in the venting tables shall ...
Los Angeles Plumbing Code > 5 Water Heaters > 510.0 Sizing of Category I Venting Systems > 510.2 Multiple Appliance Vent Table 510.2(1) Through Table 510.2(9) > 510.2.5 Elbow Reduction
803.2.5 Chimneys and Vents, Elbow Reduction
For each elbow up to and including 45 degrees (0.79 rad) in the common vent, the maximum common vent capacity listed in the venting tables shall ...
Los Angeles Mechanical Code > 8 Chimneys and Vents > 803.0 Sizing of Category I Venting Systems > 803.2 Multiple Appliance Vent Table 803.2(1) Through Table 803.2(9) > 803.2.5 Elbow Reduction
803.2.5 Chimneys and Vents, Elbow Reduction
For each elbow up to and including 45 degrees (0.79 rad) in the common vent, the maximum common vent capacity listed in the venting tables shall ...
Los Angeles Mechanical Code > 8 Chimneys and Vents > 803.0 Sizing of Category Venting Systems > 803.2 Multiple Appliance Vent Table 803.2(1) Through Table 803.2(9) > 803.2.5 Elbow Reduction
5.508.2.1.4 Nonresidential Mandatory Measures, Elbows
Short radius elbows are only permitted where space limitations prohibit use of long radius elbows ...
Los Angeles Green Building Code > 5 Nonresidential Mandatory Measures > 5.508 Outdoor Air Quality > 5.508.2 Supermarket Refrigerant Leak Reduction > 5.508.2.1 Refrigerant Piping > 5.508.2.1.4 Elbows
5.508.2.1.4 Nonresidential Mandatory Measures, Elbows
Short radius elbows are only permitted where space limitations prohibit use of long radius elbows ...
Los Angeles Green Building Code > 5 Nonresidential Mandatory Measures > 5.508 Outdoor Air Quality > 5.508.2 Supermarket Refrigerant Leak Reduction > 5.508.2.1 Refrigerant Piping > 5.508.2.1.4 Elbows
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE