1926.1002(g)(2)(iv) EIS, FER, and FSB Shall Be Calculated
Related Code Sections
1926.1002(g)(2)(iv) Rollover Protective Structures; Overhead Protection, EIS, FER, and FSB Shall Be Calculated
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(g) Static Test > 1926.1002(g)(2) Test Procedure > 1926.1002(g)(2)(iv) EIS, FER, and FSB Shall Be Calculated
1926.1002(j) Rollover Protective Structures; Overhead Protection, Definitions Applicable to This Section
under the L m - D m curve;
FER
=
Factor of energy ratio, FER = E u E is ; also, FER = E u E ir ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(j) Definitions Applicable to This Section
1926.1002(g)(1) Rollover Protective Structures; Overhead Protection, Test Conditions
be instrumented with the necessary recording equipment to obtain the required load-deflection data to be used in calculating FSB (see paragraph (j)(3 ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(g) Static Test > 1926.1002(g)(1) Test Conditions
1926.1002(g)(2)(i)(A) Rollover Protective Structures; Overhead Protection,
The strain energy absorbed by the frame is equal to the required input energy (Eis); ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(g) Static Test > 1926.1002(g)(2) Test Procedure > 1926.1002(g)(2)(i) > 1926.1002(g)(2)(i)(A)
1926.1002(g)(2)(i) Rollover Protective Structures; Overhead Protection,
The side-load application shall be at the upper extremity of the frame upright at a 90° angle to the centerline of the vehicle. The side load L shall ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(g) Static Test > 1926.1002(g)(2) Test Procedure > 1926.1002(g)(2)(i)