• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R703.9.4 EIFS/EIFS With Drainage Installation

Georgia State Minimum Standard One and Two Family Dwelling Code > 7 Wall Covering > R703 Exterior Covering > R703.9 Exterior Insulation and Finish System (EIFS)/EIFS With Drainage > R703.9.4 EIFS/EIFS With Drainage Installation
JUMP TO FULL CODE CHAPTER
AMENDMENT
This section has been amended at the state or city level.
All EIFS shall be installed in accordance with the manufacturer's installation instructions and the requirements of this section. All EIFS shall be from manufacturers with a current ICC Evaluation Report and shall be installed in accordance with ANSI/EIMA 99A, ASTM C 1397, ASTM C 1535, ASTM E 2273, ICC EIFS Evaluation Reports, the manufacturer's installation instructions and the requirements of this section.
(Effective January 1, 2014)

R703.9.4.1 Terminations

The EIFS shall terminate not less than 6 inches (152 mm) above the finished ground level.

R703.9.4.2 Decorative Trim

Decorative trim shall not be face nailed though the EIFS.

Related Code Sections


R703.9.4.1 Wall Covering, Terminations
The EIFS shall terminate not less than 6 inches (152 mm) above the finished ground level ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 7 Wall Covering > R703 Exterior Covering > R703.9 Exterior Insulation and Finish System (EIFS)/EIFS With Drainage > R703.9.4 EIFS/EIFS With Drainage Installation > R703.9.4.1 Terminations
1407.4.1 Exterior Walls, EIFS With Drainage
EIFS with drainage shall have an average minimum drainage efficiency of 90 percent when tested in accordance the requirements of ASTM E2273 ...
Georgia State Minimum Standard Building Code > 14 Exterior Walls > 1407 Exterior Insulation and Finish Systems (EIFS) > 1407.4 Weather Resistance > 1407.4.1 EIFS With Drainage
1408.4.1 Exterior Walls, EIFS With Drainage
EIFS with drainage shall have an average minimum drainage efficiency of 90 percent when tested in accordance the requirements of ASTM E 2273 ...
Georgia State Minimum Standard Building Code > 14 Exterior Walls > 1408 Exterior Insulation and Finish Systems (EIFS) > 1408.4 Weather Resistance > 1408.4.1 EIFS With Drainage
R703.9 Wall Covering, Exterior Insulation and Finish System (EIFS)/EIFS With Drainage
with drainage shall be provided in accordance with the requirements of Section R703.4. EIFS with drainage shall be installed in accordance ...
Georgia State Minimum Standard One and Two Family Dwelling Code > 7 Wall Covering > R703 Exterior Covering > R703.9 Exterior Insulation and Finish System (EIFS)/EIFS With Drainage
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE