Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 1005 Egress Width

Building Code 2009 of Alabama > 10 Means of Egress > 1005 Egress Width
JUMP TO FULL CODE CHAPTER

1005.1 Minimum Required Egress Width

The means of egress width shall not be less than required by this section. The total width of means of egress in inches (mm) shall not be less than the total occupant load served by the means of egress multiplied by 0.3 inch (7.62 mm) per occupant for stairways and by 0.2 inch (5.08 mm) per occupant for other egress components. The width shall not be less than specified elsewhere in this code. Multiple means of egress shall be sized such that the loss of any one means of egress shall not reduce the available capacity to less than 50 percent of the required capacity. The maximum capacity required from any story of a building shall be maintained to the termination of the means of egress.
Exception: Means of egress complying with Section 1028.

1005.2 Door Encroachment

Doors, when fully opened, and handrails shall not reduce the required means of egress width by more than 7 inches (178 mm). Doors in any position shall not reduce the required width by more than one-half. Other nonstructural projections such as trim and similar decorative features shall be permitted to project into the required width a maximum of 11/2 inches (38 mm) on each side.
Exception: The restrictions on a door swing shall not apply to doors within individual dwelling units and sleeping units of Group R-2 and dwelling units of Group R-3.

1005.3 Door Hardware Encroachment

Surface-mounted latch release hardware shall be exempt from inclusion in the 7-inch (178 mm) maximum projection requirement of Section 1005.2 when:
  1. The hardware is mounted to the side of the door facing the corridor width when the door is in the open position; and
  2. The hardware is mounted not less than 34 inches (865 mm) or more than 48 inches (1220 mm) above the finished floor.

Related Code Sections


Section 1005 Means of Egress, Egress Width
The means of egress width shall not be less than required by this section. The total width of means of egress in inches (mm) shall not be less ...
Fire Code 2009 of Alabama > 10 Means of Egress > 1005 Egress Width
Section 1005 Means of Egress, Egress Width
The means of egress width shall not be less than required by this section. The total width of means of egress in inches (mm) shall not be less ...
Building Code 2009 of Alabama > 10 Means of Egress > 1005 Egress Width
4604.7 Construction Requirements for Existing Buildings, Minimum Required Egress Width
The means of egress width shall not be less than as required by the code under which constructed but not less than as required by this section. The ...
Fire Code 2009 of Alabama > 46 Construction Requirements for Existing Buildings > 4604 Means of Egress for Existing Buildings > 4604.7 Minimum Required Egress Width
1005.3 Means of Egress, Door Hardware Encroachment
: The hardware is mounted to the side of the door facing the corridor width when the door is in the open position; and The hardware is mounted ...
Building Code 2009 of Alabama > 10 Means of Egress > 1005 Egress Width > 1005.3 Door Hardware Encroachment
1028.6.1 Means of Egress, Without Smoke Protection
The clear width of the means of egress shall provide sufficient capacity in accordance with all of the following, as applicable: At least 0.3 ...
Fire Code 2009 of Alabama > 10 Means of Egress > 1028 Assembly > 1028.6 Width of Means of Egress for Assembly > 1028.6.1 Without Smoke Protection
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING