1010.1.4.1.1 Egress Component
JUMP TO FULL CODE CHAPTER
A revolving door used as a component of a means of egress shall comply with Section 1010.1.4.1 and the following three conditions:
- Revolving doors shall not be given credit for more than 50 percent of the minimum width or required capacity.
- Each revolving door shall be credited with a capacity based on not more than a 50-person occupant load.
- Each revolving door shall provide for egress in accordance with BHMA A156.27 with a breakout force of not more than 130 pounds (578 N).
Related Code Sections
1008.1.4.1.1 Means of Egress, Egress Component
A revolving door used as a component of a means of egress shall comply with Section 1008.1.4.1 and the following three conditions: Revolving ...
Fire Code 2009 of Massachusetts > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.4 Special Doors > 1008.1.4.1 Revolving Doors > 1008.1.4.1.1 Egress Component
1008.1.4.1.1 Means of Egress, Egress Component
A revolving door used as a component of a means of egress shall comply with Section 1008.1.4.1 and the following three conditions: Revolving ...
MA State Building Code, 8th ed, Base Volume > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.4 Special Doors > 1008.1.4.1 Revolving Doors > 1008.1.4.1.1 Egress Component
1010.1.4.1.1 Means of Egress, Egress Component
A revolving door used as a component of a means of egress shall comply with Section 1010.1.4.1 and the following three conditions:
Revolving ...
MA State Building Code, 9th ed, Base Volume > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.4 Special Doors > 1010.1.4.1 Revolving Doors > 1010.1.4.1.1 Egress Component
4604.10.1 Construction Requirements for Existing Buildings, Egress Component
A revolving door used as a component of a means of egress shall comply with Section 4604.10 and all of the following conditions: Revolving doors ...
Fire Code 2009 of Massachusetts > 46 Construction Requirements for Existing Buildings > 4604 Means of Egress for Existing Buildings > 4604.10 Revolving Doors > 4604.10.1 Egress Component
1005.3.2 Means of Egress, Other Egress Components
The capacity, in inches, of means of egress components other than stairways shall be calculated by multiplying the occupant load served ...
MA State Building Code, 9th ed, Base Volume > 10 Means of Egress > 1005 Means of Egress Sizing > 1005.3 Required Capacity Based on Occupant Load > 1005.3.2 Other Egress Components