404.6 Efficiency Unit
Go To Full Code Chapter
Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements:
- A unit occupied by not more than one occupant shall have a minimum clear floor area of 120 square feet (11.2 m2). A unit occupied by not more than two occupants shall have a minimum clear floor area of 220 square feet (20.4 m2). A unit occupied by three occupants shall have a minimum clear floor area of 320 square feet (29.7 m2). These required areas shall be exclusive of the areas required by Items 2 and 3.
- The unit shall be provided with a kitchen sink, cooking appliance and refrigeration facilities, each having a minimum clear working space of 30 inches (762 mm) in front. Light and ventilation conforming to this code shall be provided.
- The unit shall be provided with a separate bathroom containing a water closet, lavatory and bathtub or shower.
- The maximum number of occupants shall be three.
Upcodes Diagrams
Related Code Sections
404.6 Light, Ventilation and Occupancy Limitations, Efficiency Unit
Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements: A unit occupied by not more than one ...
404.6 Light, Ventilation and Occupancy Limitations, Efficiency Unit
Nothing in this section shall prohibit an efficiency living unit from meeting the following requirements: A unit occupied by not more than one ...
1207.4 Interior Environment, Efficiency Dwelling Units
An efficiency living unit shall conform to the requirements of the code except as modified herein: The unit shall have a living room of not less ...
1208.4 Interior Environment, Efficiency Dwelling Units
An efficiency living unit shall conform to the requirements of the code except as modified herein:
The unit shall have a living room of not less ...
C404.8 [CE] Commercial Energy Efficiency, Drain Water Heat Recovery Units
flow. For Group R occupancies, the efficiency of drain water heat recovery unit efficiency shall be in accordance with CSA B55.1 ...