1910.265(e)(5) Edgers
JUMP TO FULL CODE CHAPTER
—
Where vertical arbor edger saws are located ahead of the main saw, they shall be so guarded that an employee cannot contact any part of the edger saw from his normal position.
Edgers shall not be located in the main roll case behind the head saws.
Edgers shall be provided with safety fingers or other approved methods of preventing kickbacks or guarding against them. A barricade in line with the edger, if properly fenced off, may be used if safety fingers are not feasible to install.
A controlling device shall be installed and located so that the operator can stop the feed mechanism without releasing the tension of the pressure rolls.
Live rolls and tailing devices in back of edger shall operate at a speed not less than the speed of the edger feed rolls.
The top and the openings in end and side frames of edgers shall be adequately guarded and gears and chains shall be fully housed. Guards may be hinged or otherwise arranged to permit oiling and the removal of saws.
All edgers shall be equipped with pressure feed rolls.
Pressure feed rolls on edgers shall be guarded against accidental contact.
Related Code Sections
1910.265(e)(5) Special Industries, Edgers
vertical arbor edger saws are located ahead of the main saw, they shall be so guarded ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(e) Log Breakdown and Related Machinery and Facilities > 1910.265(e)(5) Edgers
1910.265(e)(5)(iii) Special Industries, Antikickback Devices
Edgers shall be provided with safety fingers or other approved methods of preventing kickbacks or guarding against them. A barricade in line ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(e) Log Breakdown and Related Machinery and Facilities > 1910.265(e)(5) Edgers > 1910.265(e)(5)(iii) Antikickback Devices
1910.265(e)(5)(ii)(b) Special Industries,
All edgers shall be equipped with pressure feed rolls ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(e) Log Breakdown and Related Machinery and Facilities > 1910.265(e)(5) Edgers > 1910.265(e)(5)(ii) Guards > 1910.265(e)(5)(ii)(b)
1910.265(e)(5)(i)(b) Special Industries,
Edgers shall not be located in the main roll case behind the head saws ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(e) Log Breakdown and Related Machinery and Facilities > 1910.265(e)(5) Edgers > 1910.265(e)(5)(i) Location > 1910.265(e)(5)(i)(b)
1910.265(e)(5)(ii)(c) Special Industries,
Pressure feed rolls on edgers shall be guarded against accidental contact ...
OSHA 1910 General Industry > R Special Industries > 1910.265 Sawmills > 1910.265(e) Log Breakdown and Related Machinery and Facilities > 1910.265(e)(5) Edgers > 1910.265(e)(5)(ii) Guards > 1910.265(e)(5)(ii)(c)