• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

N1102.2.3 (R402.2.3) Eave Baffle

Residential Code 2018 of Kansas > 11 [RE] Energy Efficiency > N1102 (R402) Building Thermal Envelope > N1102.2 (R402.2) Specific Insulation Requirements (Prescriptive) > N1102.2.3 (R402.2.3) Eave Baffle
JUMP TO FULL CODE CHAPTER
For air-permeable insulations in vented attics, a baffle shall be installed adjacent to soffit and eave vents. Baffles shall maintain an opening equal or greater than the size of the vent. The baffle shall extend over the top of the attic insulation. The baffle shall be permitted to be any solid material.

Related Code Sections


N1102.2.3 [RE] Energy Efficiency, (R402.2.3) Eave Baffle
For air-permeable insulations in vented attics, a baffle shall be installed adjacent to soffit and eave vents. Baffles shall maintain an opening ...
Residential Code 2018 of Kansas > 11 [RE] Energy Efficiency > N1102 (R402) Building Thermal Envelope > N1102.2 (R402.2) Specific Insulation Requirements (Prescriptive) > N1102.2.3 (R402.2.3) Eave Baffle
R402.2.3 [RE] Residential Energy Efficiency, Eave Baffle
For air-permeable insulations in vented attics, a baffle shall be installed adjacent to soffit and eave vents. Baffles shall maintain an opening ...
Energy Conservation Code 2018 of Kansas > 4 [RE] Residential Energy Efficiency > R402 Building Thermal Envelope > R402.2 Specific Insulation Requirements (Prescriptive) > R402.2.3 Eave Baffle
R804.3.2.1.1 Roof-Ceiling Construction, Eave Overhang
Eave overhangs shall not exceed 24 inches (610 mm) measured horizontally ...
Residential Code 2018 of Kansas > 8 Roof-Ceiling Construction > R804 Cold-Formed Steel Roof Framing > R804.3 Roof Construction > R804.3.2 Roof Rafters > R804.3.2.1 Minimum Roof Rafter Sizes > R804.3.2.1.1 Eave Overhang
8.9.3.4 Installation Requirements, Minimum Distance Between Sprinklers
Sprinklers shall be not located within the maximum protection area of any other sprinkler unless required by 8.9.4.1.4.1 or separated by baffles ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 8 Installation Requirements > 8.9* Extended Coverage Sidewall Spray Sprinklers > 8.9.3 Sprinkler Spacing (Extended Coverage Sidewall Spray Sprinklers) > 8.9.3.4 Minimum Distance Between Sprinklers
8.10.3 Installation Requirements, Distances Between Sprinklers
required by 8.10.7.1.5.1, or unless separated by baffles that comply with the following: Baffles shall be arranged to protect the actuating ...
Standard for the Installation of Sprinkler Systems 2016 of Kansas > 8 Installation Requirements > 8.10 Residential Sprinklers > 8.10.3 Distances Between Sprinklers
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING