• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1211.7 Earthquake-Actuated Gas Shutoff Valves

California Plumbing Code 2019 > 12 Fuel Gas Piping > 1211.0 Electrical Bonding and Grounding > 1211.7 Earthquake-Actuated Gas Shutoff Valves
JUMP TO FULL CODE CHAPTER
Earthquake-actuated gas shutoff valves designed to automatically shut off the gas at the location of the valve in the event of a seismic disturbance and certified by the State Architect as conforming to California Code of Regulations, Title 24, Part 12, Chapter 12-16-1, shall be provided for buildings when such installation is required by local ordinance. Earthquake-actuated gas shutoff valves which have not been certified by the State Architect shall be prohibited in buildings open to the public under mandatory installation by local ordinance. Installation of the valves shall be in accordance with local ordinance, and in the absence of such per the manufacturers installation instructions.

Related Code Sections


1211.7 Fuel Gas Piping, Earthquake-Actuated Gas Shutoff Valves
Earthquake-actuated gas shutoff valves designed to automatically shut oil the gas at the location of the valve in the event of a seismic disturbance ...
California Plumbing Code 2016 > 12 Fuel Gas Piping > 1211.0 Electrical Bonding and Grounding > 1211.7 Earthquake-Actuated Gas Shutoff Valves
1211.7 Fuel Gas Piping, Earthquake-Actuated Gas Shutoff Valves
Earthquake-actuated gas shutoff valves designed to automatically shut off the gas at the location of the valve in the event of a seismic disturbance ...
California Plumbing Code 2019 > 12 Fuel Gas Piping > 1211.0 Electrical Bonding and Grounding > 1211.7 Earthquake-Actuated Gas Shutoff Valves
1311.8 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Emergency Shutoff Valves
Emergency shutoff valves shall be labeled to indicate the gas they control and shall shut off only the gas to the treatment facility that they serve ...
California Plumbing Code 2019 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1311.0 Valves > 1311.8 Emergency Shutoff Valves
1312.1.3 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Emergency Shutoff Valves
at a supply manifold shall not be used for emergency shutoff. For clinical purposes, such a remote valve actuator shall not fail-closed in the event ...
California Plumbing Code 2016 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1312.0 Shutoff Valves > 1312.1 General > 1312.1.3 Emergency Shutoff Valves
1208.10 Fuel Gas Piping, Shutoff Valves
Shutoff valves shall be approved and shall be selected giving consideration to pressure drop, service involved, emergency use, and reliability ...
California Plumbing Code 2016 > 12 Fuel Gas Piping > 1208.0 Gas Piping System Design, Materials, and Components > 1208.10 Shutoff Valves
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE