406.3.4.1 Dwelling Unit Separation

Building Code 2015 of Utah > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.3 Private Garages and Carports > 406.3.4 Separation > 406.3.4.1 Dwelling Unit Separation
JUMP TO FULL CODE CHAPTER
The private garage shall be separated from the dwelling unit and its attic area by means of gypsum board, not less than 1/2 inch (12.7 mm) in thickness, applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than a 5/8- inch (15.9 mm) Type X gypsum board or equivalent and 1/2-inch (12.7 mm) gypsum board applied to structures supporting the separation from habitable rooms above the garage. Door openings between a private garage and the dwelling unit shall be equipped with either solid wood doors or solid or honeycomb core steel doors not less than 13/8 inches (34.9 mm) in thickness, or doors in compliance with Section 716.5.3 with a fire protection rating of not less than 20 minutes. Doors shall be self-closing and self-latching.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


406.3.2.1 Special Detailed Requirements Based on Occupancy and Use, Dwelling unit separation
The private garage shall be separated from the dwelling unit and its attic area by means of gypsum board, not less than 1 / 2 inch (12.7 mm ...
Building Code 2018 of Utah > 4 Special Detailed Requirements Based on Occupancy and Use > 406 Motor-Vehicle-Related Occupancies > 406.3 Private garages and carports > 406.3.2 Separation > 406.3.2.1 Dwelling unit separation
406.3.4.1 Special Detailed Requirements Based on Use and Occupancy, Dwelling Unit Separation
The private garage shall be separated from the dwelling unit and its attic area by means of gypsum board, not less than 1 / 2 inch (12.7 mm ...
Building Code 2015 of Utah > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies > 406.3 Private Garages and Carports > 406.3.4 Separation > 406.3.4.1 Dwelling Unit Separation
1301.6.4 Performance Compliance Methods, Tenant and dwelling unit separations
Evaluate the fire-resistance rating of floors and walls separating tenants, including dwelling units, and not evaluated under Sections 1301.6.3 ...
Existing Building Code 2018 of Utah > 13 Performance Compliance Methods > 1301 General > 1301.6 Evaluation process > 1301.6.4 Tenant and dwelling unit separations
1401.6.4 Performance Compliance Methods, Tenant and Dwelling Unit Separations
Evaluate the fire-resistance rating of floors and walls separating tenants, including dwelling units, and not evaluated under Sections 1401.6.3 ...
Existing Building Code 2015 of Utah > 14 Performance Compliance Methods > 1401 General > 1401.6 Evaluation Process > 1401.6.4 Tenant and Dwelling Unit Separations
718.4.2 Fire and Smoke Protection Features, Groups R-1 and R-2
units and in all Group R-1 buildings. Draftstopping shall be installed above, and in line with, sleeping unit and dwelling unit separation walls ...
Building Code 2015 of Utah > 7 Fire and Smoke Protection Features > 718 Concealed Spaces > 718.4 Draftstopping in Attics > 718.4.2 Groups R-1 and R-2
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US