// CODE SNIPPET
(4) Duty Rating and Overload Protection on Platform Lift and Stairway Chairlift Motors
National Electrical Code 2020 of Illinois > 6 Special Equipment > 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts > 620.61 Overcurrent Protection > (B) Overload Protection for Motors > (4) Duty Rating and Overload Protection on Platform Lift and Stairway Chairlift Motors
Related Code Sections
(4) Special Equipment, Duty Rating and Overload Protection on Platform Lift and Stairway Chairlift Motors
Duty on platform lift and stairway chairlift driving machine motors shall be rated as intermittent. Such motors shall be permitted to be protected ...
National Electrical Code 2017 of Illinois > 6 Special Equipment > 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts > 620.61 Overcurrent Protection > (B) Overload Protection for Motors > (4) Duty Rating and Overload Protection on Platform Lift and Stairway Chairlift Motors
(4) Special Equipment, Duty Rating and Overload Protection on Platform Lift and Stairway Chairlift Motors
Duty on platform lift and stairway chairlift driving machine motors shall be rated as intermittent. Such motors shall be permitted to be protected ...
National Electrical Code 2020 of Illinois > 6 Special Equipment > 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts > 620.61 Overcurrent Protection > (B) Overload Protection for Motors > (4) Duty Rating and Overload Protection on Platform Lift and Stairway Chairlift Motors
(2) Special Equipment, Duty Rating on Escalator Motors
Duty on escalator and moving walk driving machine motors shall be rated as continuous. Such motors shall be protected against overload in accordance ...
(1) Special Equipment, Duty Rating on Elevator, Dumbwaiter, and Motor-Generator Sets Driving Motors
Duty on elevator and dumbwaiter driving machine motors and driving motors of motorgenerators used with generator field control shall be rated ...
National Electrical Code 2020 of Illinois > 6 Special Equipment > 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts > 620.61 Overcurrent Protection > (B) Overload Protection for Motors > (1) Duty Rating on Elevator, Dumbwaiter, and Motor-Generator Sets Driving Motors
(1) Special Equipment, Duty Rating on Elevator, Dumbwaiter, and Motor-Generator Sets Driving Motors
Duty on elevator and dumbwaiter driving machine motors and driving motors of motor-generators used with generator field control shall be rated ...
National Electrical Code 2017 of Illinois > 6 Special Equipment > 620 Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts > 620.61 Overcurrent Protection > (B) Overload Protection for Motors > (1) Duty Rating on Elevator, Dumbwaiter, and Motor-Generator Sets Driving Motors