// CODE SNIPPET
1910.147(c)(5)(ii)(A) Durable
JUMP TO FULL CODE CHAPTER
Lockout and tagout devices shall be capable of withstanding the environment to which they are exposed for the maximum period of time that exposure is expected.
Tagout devices shall be constructed and printed so that exposure to weather conditions or wet and damp locations will not cause the tag to deteriorate or the message on the tag to become illegible.
Tags shall not deteriorate when used in corrosive environments such as areas where acid and alkali chemicals are handled and stored.
Related Code Sections
1910.147(c)(5)(ii)(A) General Environmental Controls, Durable
Lockout and tagout devices shall be capable of withstanding the environment to which they are exposed for the maximum period of time that exposure ...
OSHA 1910 General Industry > J General Environmental Controls > 1910.147 The Control of Hazardous Energy (Lockout/Tagout) > 1910.147(c) General > 1910.147(c)(5) Protective Materials and Hardware > 1910.147(c)(5)(ii) > 1910.147(c)(5)(ii)(A) Durable
1910.303(e)(2) Electrical, Durability
The marking shall be of sufficient durability to withstand the environment involved ...
OSHA 1910 General Industry > S Electrical > 1910.303 General > 1910.303(e) Marking > 1910.303(e)(2) Durability
1910.184(e)(1) Materials Handling and Storage, Sling Identification
Alloy steel chain slings shall have permanently affixed durable identification stating size, grade, rated capacity, and reach ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(e) Alloy Steel Chain Slings > 1910.184(e)(1) Sling Identification
1910.184(g)(1) Materials Handling and Storage, Sling Marking
Each metal mesh sling shall have permanently affixed to it a durable marking that states the rated capacity for vertical basket hitch and choker ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(g) Metal Mesh Slings > 1910.184(g)(1) Sling Marking
1910.308(c)(2) Electrical, Marking
A Class 2 or Class 3 power supply unit shall be durably marked where plainly visible to indicate the class of supply and its electrical rating ...
OSHA 1910 General Industry > S Electrical > 1910.308 Special Systems > 1910.308(c) Class 1, Class 2, and Class 3 Remote Control, Signaling, and Power-Limited Circuits > 1910.308(c)(2) Marking