422.1.2 [DSA-AC]
JUMP TO FULL CODE CHAPTER
Effective January 1, 1990, in new
construction and those existing facilities which occupancy
type are listed in Tables 422.1 and 4-4 for public
use, which apply for permit to undertake construction,
structural alterations, repairs or improvement which
exceed 50 percent of the square footage of the entire
facility, shall install water closets, urinals, lavatories and
drinking fountains as stipulated in Tables 422.1 and 4-4
for public use. Community and/or municipal parks with
a bleacher capacity not exceeding 500 seats shall be
exempt from the requirements of this section and Tables
422.1 and 4-4. Each bathroom shall comply with Part 2,
Chapter 11A and 11B of the California Building Code.
Notes:
TYPE OF BUILDING OR OCCUPANCY2 | WATER CLOSETS (FIXTURES PER PERSON) |
URINALS (FIXTURES PER MALE) |
LAVATORIES (FIXTURES PER PERSON) |
BATHTUBS OR SHOWERS (FIXTURES PER PERSON) |
DRINKING FOUNTAINS (FIXTURES PER PERSON) |
|
---|---|---|---|---|---|---|
Day Use Public Beaches1,2 |
Male | Female | May be substituted for up to two-thirds of the water closets required | |||
1 1-100 | 1 1-100 | |||||
No sex designated 1 1-500 Minimum of 2 |
||||||
Picnic Areas | Male | Female | ||||
1 1-50 | 1 1-50 | |||||
Overnight Use Public Beaches2 |
1 1-7.5 campsites3 | May be substituted for up to one-third of the water closets required3 | 1 1-12.5 campsites4 | |||
1 1-7.5 campsites3 | ||||||
Organized Camps | 1 1-153 | 1 1-15 | 1 1-156 | Minimum 1 per camp |
- 1 Toilets shall be located in accordance with actual use patterns on the beach. The reasonable intent of the toilet requirements is that it should apply on the basis of average daily use during periods of peak use. The health officer may determine how many days the population standard may be exceeded.
- 2 Laundry facilities are not required, but if they are provided, must be a minimum of two laundry trays or a washing machine.
- 3 Toilet facilities shall not be farther than 400 feet from any lot or campsite.
- 4 Showers are not required, but it provided, they shall be provided on the indicated ratio. Outdoor rinse-off showers may be cold water only.
- 5 Toilets shall be located within 300 feet from the living accommodations they serve.
- 6 Showers shall be provided in the living area or in a centrally located structure.
Exception: Intermittent short-term organized camps are not required to provide shower facilities, but it provided, they shall comply with this part.
Related Code Sections
422.1.2 Plumbing Fixtures and Fixture Fittings, [DSA-AC]
Effective January 1, 1990, in new
construction and those existing facilities which occupancy
type are listed in Tables 422.1 and 4-4 for public
use ...
California Plumbing Code 2016 > 4 Plumbing Fixtures and Fixture Fittings > 422.0 Minimum Number of Required Fixtures > 422.1 Fixture Count > 422.1.2 [DSA-AC]
5-301 Access to Public Buildings by Persons With Disabilities, Division of the State Architect, Access Compliance, Acceptance of Product
The procedure for the DSA-AC acceptance of manufactured products is detailed in this article. All products require prior evaluation by a recognized ...
California Administrative Code 2016 > 5 Access to Public Buildings by Persons With Disabilities > 3 Acceptance of Detectable Warning and Directional Surface Products for Manufacturers and Design Professionals January 1, 2001 > 5-301 Division of the State Architect, Access Compliance, Acceptance of Product
5-301 Access to Public Buildings by Persons With Disabilities, Division of the State Architect, Access Compliance, Acceptance of Product
The procedure for the DSA-AC acceptance of manufactured products is detailed in this article. All products require prior evaluation by a recognized ...
California Administrative Code 2019 > 5 Access to Public Buildings by Persons With Disabilities > 3 Acceptance of Detectable Warning and Directional Surface Products for Manufacturers and Design Professionals January 1, 2001 > 5-301 Division of the State Architect, Access Compliance, Acceptance of Product
1.9.1.1 Scope and Administration, Adopting Agency Identification
Division of the State Architect-Access Compliance amendments in this code appear preceded with the acronym [DSA-AC] ...
California Existing Building Code 2016 > 1 Scope and Administration > 1.9 Division of the State Architect > 1.9.1 Division of the State Architect-Access Compliance > 1.9.1.1 Adopting Agency Identification
1.9.1.1 Scope and Administration, Adopting Agency Identification
Division of the State Architect-Access Compliance amendments in this code appear preceded with the acronym [DSA-AC] ...
California Existing Building Code 2019 > 1 Scope and Administration > 1.9 Division of the State Architect > 1.9.1 Division of the State Architect—Access Compliance - Reserved > 1.9.1.1 Adopting Agency Identification