1926.1003(d) Drop Test Procedures
JUMP TO FULL CODE CHAPTER
The same frame shall be subjected to the drop test following either the static or dynamic test.
A solid steel sphere or material of equivalent spherical dimension weighing 100 lb (45.4 kg) shall be dropped once from a height 10 ft (3.08 m) above the overhead cover.
The point of impact shall be on the overhead cover at a point within the zone of protection as shown in Figure W-26, which is furthest removed from major structural members.
Related Code Sections
1926.1003(d) Rollover Protective Structures; Overhead Protection, Drop Test Procedures
The same frame shall be subjected to the drop test following either the static or dynamic test ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1003 Overhead Protection for Operators of Agricultural and Industrial Tractors > 1926.1003(d) Drop Test Procedures
1926.1002(h)(2) Rollover Protective Structures; Overhead Protection, Test Procedure
The frame shall be evaluated by imposing dynamic loading to the rear, followed by a load to the side on the same frame. The pendulum dropped from ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(h) Dynamic Test > 1926.1002(h)(2) Test Procedure
1926.1001(e) Rollover Protective Structures; Overhead Protection, Test Procedure
The test procedure shall include the following, in the sequence indicated ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1001 Minimum Performance Criteria for Rollover Protective Structures for Designated Scrapers, Loaders, Dozers, Graders, and Crawler Tractors > 1926.1001(e) Test Procedure
1926.1002(g)(2) Rollover Protective Structures; Overhead Protection, Test Procedure
The test procedure shall be repeated on the same frame using L (rear ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1002 Protective Frames (Roll-Over Protective Structures, Known as ROPS) for Wheel-Type Agricultural and Industrial Tractors Used in Construction > 1926.1002(g) Static Test > 1926.1002(g)(2) Test Procedure
1926.1003(f)(2) Rollover Protective Structures; Overhead Protection, Drop Test Performance Requirements
Instantaneous deformation due to impact of the sphere shall not enter the protected zone as illustrated in Figures W-25, W-26, and W-28 ...
OSHA 1926 Construction > W Rollover Protective Structures; Overhead Protection > 1926.1003 Overhead Protection for Operators of Agricultural and Industrial Tractors > 1926.1003(f) Performance Requirements > 1926.1003(f)(2) Drop Test Performance Requirements