408.2 Drips
JUMP TO FULL CODE CHAPTER
Where wet gas exists, a drip shall be provided at any point in the line of pipe where condensate could collect. A drip shall also be provided at the outlet of the meter and shall be installed so as to constitute a trap wherein an accumulation of condensate will shut off the flow of gas before the condensate will run back into the meter.
Related Code Sections
408.2 Gas Piping Installations, Drips
Where wet gas exists, a drip shall be provided at any point in the line of pipe where condensate could collect. A drip shall also be provided ...
Georgia State Minimum Standard Gas Code > 4 Gas Piping Installations > 408 (IFGC) Drips and Sloped Piping > 408.2 Drips
408.2 Gas Piping Installations, Drips
Where wet gas exists, a drip shall be provided at any point in the line of pipe where condensate could collect. A drip shall be provided ...
Georgia State Minimum Standard Gas Code > 4 Gas Piping Installations > 408 (IFGC) Drips and Sloped Piping > 408.2 Drips
1507.2.8.3 Roof Assemblies and Rooftop Structures, Drip Edge
A drip edge shall be provided at eaves and rake edges of shingle roofs. Adjacent segments of the drip edge shall be lapped not less than 2 inches (51 ...
Georgia State Minimum Standard Building Code > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.2 Asphalt Shingles > 1507.2.8 Flashings > 1507.2.8.3 Drip Edge
1507.2.9.3 Roof Assemblies and Rooftop Structures, Drip Edge
Provide drip edge at eaves and gables of shingle roofs. Overlap to be a minimum of 2 inches (51 mm). Eave drip edges shall extend 1 / 4 inch (6.4 ...
Georgia State Minimum Standard Building Code > 15 Roof Assemblies and Rooftop Structures > 1507 Requirements for Roof Coverings > 1507.2 Asphalt Shingles > 1507.2.9 Flashings > 1507.2.9.3 Drip Edge
5707.6.2 Flammable and Combustible Liquids, Drip Control
Operators shall place a drip pan or an absorbent pillow under the nozzle and each fuel fill opening prior to and during dispensing operations ...
Georgia State Minimum Fire Prevention Code > 57 Flammable and Combustible Liquids > 5707 On-Demand Mobile Fueling Operations > 5707.6 Operations > 5707.6.2 Drip Control