[P] 2902.5 Drinking Fountain Location
JUMP TO FULL CODE CHAPTER
Drinking fountains shall not be required to be located in individual tenant spaces provided that public drinking fountains are located within a distance of travel of 500 feet (152 m) of the most remote location in the tenant space and not more than one story above or below the tenant space. Where the tenant space is in a covered or open mall, such distance shall not exceed 300 feet (91 440 mm). Drinking fountains shall be located on an accessible route.
Related Code Sections
2902.5 Plumbing Systems, Drinking Fountain Location
Drinking fountains shall not be required to be located in individual tenant spaces provided that public drinking fountains are located within ...
Building Code 2018 of Illinois > 29 Plumbing Systems > 2902 Minimum Plumbing Facilities > 2902.5 Drinking Fountain Location
602.5 Plumbing Elements and Facilities, Spout Location
, including bumpers.
Figure 602.5
Drinking Fountain Spout Location
...
2018 Illinois Accessibility Code > 6 Plumbing Elements and Facilities > 602 Drinking Fountains > 602.5 Spout Location
1111.2 Accessibility, Directional Signage
for standing persons are not located adjacent to each other, directional signage shall be provided indicating the location of the other drinking fountains ...
1109.5 Accessibility, Drinking Fountains
Where drinking fountains are provided on an exterior site, on a floor or within a secured area, the drinking fountains shall be provided ...
Building Code 2018 of Illinois > 11 Accessibility > 1109 Other Features and Facilities > 1109.5 Drinking Fountains
202.5.2.4 Scoping Requirements, Drinking Fountains
If drinking fountains are required in the facility by the Illinois Plumbing Code , at least one accessible drinking fountain, or bottled drinking ...
2018 Illinois Accessibility Code > 2 Scoping Requirements > 202 Existing Buildings and Facilities > 202.5 Alterations to Qualified Historic Buildings and Facilities > 202.5.2 Alterations to Historically Interpreted Buildings > 202.5.2.4 Drinking Fountains