• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.800(q) Drilling

OSHA 1926 Construction > S Underground Construction, Caissons, Cofferdams, and Compressed Air > 1926.800 Underground Construction > 1926.800(q) Drilling
JUMP TO FULL CODE CHAPTER

1926.800(q)(1)

A competent person shall inspect all drilling and associated equipment prior to each use. Equipment defects affecting safety shall be corrected before the equipment is used.

1926.800(q)(2)

The drilling area shall be inspected for hazards before the drilling operation is started.

1926.800(q)(3)

Employees shall not be allowed on a drill mast while the drill bit is in operation or the drill machine is being moved.

1926.800(q)(4)

When a drill machine is being moved from one drilling area to another, drill steel, tools, and other equipment shall be secured and the mast shall be placed in a safe position.

1926.800(q)(5)

Receptacles or racks shall be provided for storing drill steel located on jumbos.

1926.800(q)(6)

Employees working below jumbo decks shall be warned whenever drilling is about to begin.

1926.800(q)(7)

Drills on columns shall be anchored firmly before starting drilling, and shall be retightened as necessary thereafter.

1926.800(q)(8)

1926.800(q)(8)(i)

The employer shall provide mechanical means on the top deck of a jumbo for lifting unwieldy or heavy material.

1926.800(q)(8)(iii)

Jumbo decks more than 10 feet (3.05 m) in height shall be equipped with guardrails on all open sides, excluding access openings of platforms, unless an adjacent surface provides equivalent fall protection.

1926.800(q)(8)(iv)

1926.800(q)(8)(iv)(A)

Only employees assisting the operator shall be allowed to ride on jumbos, unless the jumbo meets the requirements of paragraph (r)(6)(ii) of this section.

1926.800(q)(8)(iv)(B)

Jumbos shall be chocked to prevent movement while employees are working on them.

1926.800(q)(8)(v)

1926.800(q)(8)(v)(A)

Walking and working surfaces of jumbos shall be maintained to prevent the hazards of slipping, tripping and falling.

1926.800(q)(8)(v)(B)

Jumbo decks and stair treads shall be designed to be slip-resistent and secured to prevent accidental displacement.

1926.800(q)(8)(ii)

When jumbo decks are over 10 feet (3.05 m) in height, the employer shall install stairs wide enough for two persons.

1926.800(q)(9)

Scaling bars shall be available at scaling operations and shall be maintained in good condition at all times. Blunted or severely worn bars shall not be used.

1926.800(q)(10)

1926.800(q)(10)(i)

Blasting holes shall not be drilled through blasted rock (muck) or water.

1926.800(q)(10)(ii)

Employees in a shaft shall be protected either by location or by suitable barrier(s) if powered mechanical loading equipment is used to remove muck containing unfired explosives.

1926.800(q)(11)

A caution sign reading "Buried Line," or similar wording shall be posted where air lines are buried or otherwise hidden by water or debris.

Related Code Sections


1926.800(q) Underground Construction, Caissons, Cofferdams, and Compressed Air, Drilling
A competent person shall inspect all drilling and associated equipment prior to each use. Equipment defects affecting safety shall be corrected ...
OSHA 1926 Construction > S Underground Construction, Caissons, Cofferdams, and Compressed Air > 1926.800 Underground Construction > 1926.800(q) Drilling
1926.1400(c)(11) Cranes & Derricks in Construction, Dedicated Drilling Rigs
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1400 Scope > 1926.1400(c) Exclusions > 1926.1400(c)(11) Dedicated Drilling Rigs
1926.1431(o) Cranes & Derricks in Construction, Hoisting Personnel in Drill Shafts
When hoisting employees into and out of drill shafts that are up to and including 8 feet in diameter, all of the following requirements must be met ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1431 Hoisting Personnel > 1926.1431(o) Hoisting Personnel in Drill Shafts
1926.800(q)(5) Underground Construction, Caissons, Cofferdams, and Compressed Air,
Receptacles or racks shall be provided for storing drill steel located on jumbos ...
OSHA 1926 Construction > S Underground Construction, Caissons, Cofferdams, and Compressed Air > 1926.800 Underground Construction > 1926.800(q) Drilling > 1926.800(q)(5)
1926.800(q)(6) Underground Construction, Caissons, Cofferdams, and Compressed Air,
Employees working below jumbo decks shall be warned whenever drilling is about to begin ...
OSHA 1926 Construction > S Underground Construction, Caissons, Cofferdams, and Compressed Air > 1926.800 Underground Construction > 1926.800(q) Drilling > 1926.800(q)(6)
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE