• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

803 Dressing, Fitting, and Locker Rooms

2010 ADA Standards > 8 Special Rooms, Spaces, and Elements > 803 Dressing, Fitting, and Locker Rooms
JUMP TO FULL CODE CHAPTER

803.1 General

Dressing, fitting, and locker rooms shall comply with 803.

Advisory 803.1 General.  Partitions and doors should be designed to ensure people using accessible dressing and fitting rooms privacy equivalent to that afforded other users of the facility.  Section 903.5 requires dressing room bench seats to be installed so that they are at the same height as a typical wheelchair seat, 17 inches (430 mm) to 19 inches (485 mm).  However, wheelchair seats can be lower than dressing room benches for people of short stature or children using wheelchairs.

803.2 Turning Space

Turning space complying with 304 shall be provided within the room.

803.3 Door Swing

Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing.

803.4 Benches

A bench complying with 903 shall be provided within the room.

803.5 Coat Hooks and Shelves

Coat hooks provided within the room shall be located within one of the reach ranges specified in 308.  Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground.

Related Code Sections


222 Scoping Requirements, Dressing, Fitting, and Locker Rooms
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster ...
2010 ADA Standards > 2 Scoping Requirements > 222 Dressing, Fitting, and Locker Rooms
803 Special Rooms, Spaces, and Elements, Dressing, Fitting, and Locker Rooms
Dressing, fitting, and locker rooms shall comply with 803. Advisory 803.1 General.  Partitions and doors should be designed to ensure people ...
2010 ADA Standards > 8 Special Rooms, Spaces, and Elements > 803 Dressing, Fitting, and Locker Rooms
803.4 Special Rooms, Spaces, and Elements, Benches
A bench complying with 903 shall be provided within the room ...
2010 ADA Standards > 8 Special Rooms, Spaces, and Elements > 803 Dressing, Fitting, and Locker Rooms > 803.4 Benches
803.5 Special Rooms, Spaces, and Elements, Coat Hooks and Shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308.  Shelves shall be 40 inches (1015 mm ...
2010 ADA Standards > 8 Special Rooms, Spaces, and Elements > 803 Dressing, Fitting, and Locker Rooms > 803.5 Coat Hooks and Shelves
225.2.1 Scoping Requirements, Lockers
Where lockers are provided, at least 5 percent, but no fewer than one of each type, shall comply with 811. Advisory 225.2.1 Lockers.  Different ...
2010 ADA Standards > 2 Scoping Requirements > 225 Storage > 225.2 Storage > 225.2.1 Lockers
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE