• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

H 1201.0 Drawings and Specifications

Uniform Plumbing Code 2018 of Nevada > H Private Sewage Disposal Systems > H 1201.0 Drawings and Specifications
JUMP TO FULL CODE CHAPTER

H 1201.1 General

The Authority Having Jurisdiction, Health Officer, or other department having jurisdiction shall be permitted to require the following information before a permit is issued for a private sewage disposal system or at a time during the construction thereof:
  1. Plot plan drawn to scale, completely dimensioned, showing direction and approximate slope of surface, location of present or proposed retaining walls, drainage channels, water supply lines or wells, paved areas and structures on the plot, number of bedrooms or plumbing fixtures in each structure, and location of the private sewage disposal system with relation to lot lines and structures.
  2. Details of construction necessary to ensure compliance with the requirements of this appendix together with a full description of the complete installation including quality, kind, and grade of materials, equipment, construction, workmanship, and methods of assembly and installation.
  3. A log of soil formations and groundwater levels as determined by test holes dug in close proximity to a proposed seepage pit or disposal field, together with a statement of water absorption characteristics of the soil at the proposed site, as determined by approved percolation tests.
"The information contained in this appendix is not part of this American National Standard (ANS) and has not been processed in accordance with ANSI's requirements for an ANS. As such, this appendix may contain material that has not been subjected to public review or a consensus process. In addition, it does not contain requirements necessary for conformance to the standard."
The following IAPMO Installation Standard is included here for the convenience of the users of the Uniform Plumbing Code. It is not considered as a part of the Uniform Plumbing Code unless formally adopted as such. This Installation Standard is an independent, stand-alone document published by the International Association of Plumbing and Mechanical Officials and is printed herein by the expressed written permission of IAPMO.

Related Code Sections


1503.7 Alternate Water Sources for Nonpotable Applications, Drawings and Specifications
The Authority Having Jurisdiction shall require the following information to be included with or in the plot plan before a permit is issued for a gray ...
Uniform Plumbing Code 2018 of Nevada > 15 Alternate Water Sources for Nonpotable Applications > 1503.0 Gray Water Systems > 1503.7 Drawings and Specifications
H 1201.0 Private Sewage Disposal Systems, Drawings and Specifications
The Authority Having Jurisdiction, Health Officer, or other department having jurisdiction shall be permitted to require the following information ...
Uniform Plumbing Code 2018 of Nevada > H Private Sewage Disposal Systems > H 1201.0 Drawings and Specifications
C 201.0 Alternate Plumbing Systems, Definitions
are connected to the stack. Engineered Plumbing System. A system designed for a specific building project with drawings and specifications indicating ...
Uniform Plumbing Code 2018 of Nevada > C Alternate Plumbing Systems > C 201.0 Definitions
7.8.1 Documentation, General
; or by project specifications or drawings. (SIG-FUN) Where ...
National Fire Alarm and Signaling Code 2016 of Nevada > 7 Documentation > 7.8 Forms > 7.8.1 General
17.4.7.3 Initiating Devices,
(and on the drawings with its specific location and functions) shall not be required to be provided with remote alarm indicators as specified in 17.4.7 ...
National Fire Alarm and Signaling Code 2016 of Nevada > 17 Initiating Devices > 17.4 General Requirements > 17.4.7 > 17.4.7.3
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING