• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

3314.3.3 Drawings

NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.3 Design > 3314.3.3 Drawings
JUMP TO FULL CODE CHAPTER
Where design is required by this section, the drawings shall, at a minimum, include a plan view and an elevation view, with full dimensions, detailing:
  1. The location of the scaffold;
  2. Connections and attachments to the base structure, including but not limited to anchorages, fastenings, tie-ins, tie-backs, and lifelines;
  3. Any structural modifications required to the base structure;
  4. Netting with specific type and manufacturer indicated, overhead protection, or any other equipment attached to the scaffold;
  5. Any hoisting equipment located on the scaffold;
  6. Platform levels, support centers, and offsets, along with the maximum number of levels to be loaded simultaneously and the maximum loads to be imposed;
  7. For a suspended scaffold, ropes, number of clips, and counterweights, as well as outrigger beams or other support devices;
  8. For a suspended scaffold that will not be lowered to the street or deck of the sidewalk shed at the end of the shift, how the scaffold will be secured while work is not being performed; and
  9. For a supported scaffold, structural members, as well as the founding of the scaffold, including but not limited to sidewalk sheds, floors, roofs, or ground.

Related Code Sections


3314.3.3 Safeguards During Construction or Demolition, Drawings
Where design is required by this section, the drawings shall, at a minimum, include a plan view and an elevation view, with full dimensions ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3314 Scaffolds > 3314.3 Design > 3314.3.3 Drawings
106.7.3 Administration, Detailed Drawings
Drawings shall show sizes, sections, and locations of members, and such other information as may be required to indicate clearly all structural ...
NYC Building Code 2008 > 1 Administration > 106 Construction Documents > 106.7 Structural Plans > 106.7.3 Detailed Drawings
107.7.3 Administration, Detailed Drawings
Drawings shall show sizes, sections, and locations of members, and such other information as may be required to indicate clearly all structural ...
NYC Building Code 2014 > 1 Administration > 107 Construction Documents > 107.7 Structural Plans > 107.7.3 Detailed Drawings
2101.3.1 Masonry, Fireplace Drawings
The construction documents shall describe in sufficient detail the location, size and construction of masonry fireplaces. The thickness ...
NYC Building Code 2008 > 21 Masonry > 2101 General > 2101.3 Construction Documents > 2101.3.1 Fireplace Drawings
2101.3.1 Masonry, Fireplace Drawings
The construction documents shall describe in sufficient detail the location, size and construction of masonry fireplaces. The thickness ...
NYC Building Code 2014 > 21 Masonry > 2101 General > 2101.3 Construction Documents > 2101.3.1 Fireplace Drawings
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE