317.5.3 Draining of Motor Vehicle Fluids
JUMP TO FULL CODE CHAPTER
As soon as practicable after arrival, the fuel tank of motor vehicles received at salvage and wrecking facilities shall be defueled through the vehicle's fuel connection, or other approved procedure. Defueling equipment shall be listed for such purpose as a complete assembly and shall have a container capacity not exceeding 65 gallons (246 L). The fuel recovered by the defueler shall be transferred to a storage tank complying with the requirements of FC Chapter 22 or 34, as applicable. Defueling equipment shall not be used to fuel motor vehicles.
Crankcase oil and other flammable or combustible liquid waste shall be removed from motor vehicles and stored outdoors, in tanks complying with the requirements of FC Chapter 34, or, when approved, portable containers.
Related Code Sections
502.14 Exhaust Systems, Motor Vehicle Operation
In areas where motor vehicles operate, mechanical ventilation shall be provided in accordance with Section 403. Additionally, areas in which ...
NYC Mechanical Code 2008 > 5 Exhaust Systems > 502 Required Systems > 502.14 Motor Vehicle Operation
502.14 Exhaust Systems, Motor Vehicle Operation
In areas where motor vehicles operate, mechanical ventilation shall be provided in accordance with Section 403. Additionally, areas in which ...
NYC Mechanical Code 2014 > 5 Exhaust Systems > 502 Required Systems > 502.14 Motor Vehicle Operation
Section 406 Special Detailed Requirements Based on Use and Occupancy, Motor Vehicle-Related Occupancies
, open on at least two sides and unenclosed for at least 50 percent of perimeter, used for the parking or storage of passenger motor vehicles. Such ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor Vehicle-Related Occupancies
Section 406 Special Detailed Requirements Based on Use and Occupancy, Motor-Vehicle-Related Occupancies
on at least two sides and unenclosed for at least 50 percent of perimeter, used for the parking or storage of passenger motor vehicles. Such facility shall ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 406 Motor-Vehicle-Related Occupancies
3315.1.2 Safeguards During Construction or Demolition, For Motor Vehicle Use
Runways and ramps for the use of motor vehicles may consist of an earthfill or may be structurally supported. Such runways and ramps shall have ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3315 Structural Ramps, Runways, and Platforms > 3315.1 Ramps and Runways > 3315.1.2 For Motor Vehicle Use