Section 1235 [DPH] Sanitary Control of Shellfish (Plants and Operations)

Go To Full Code Chapter
1235.1 Culling Plants
Culling plants shall be located in areas free from unsanitary conditions and faulty sewage disposal. They shall be provided with an ample supply of water under adequate pressure from a source approved by the Department of Health Services for the purpose of hosing down floor and benches and cleaning the shellfish. Floors and premises shall be kept in a clean and sanitary condition.
1235.2 Plant Arrangement
Unless shellfish are shucked directly into packing containers with no further processing, the shucking and packing processes shall be done in separate rooms. There shall be installed in the partition between the two rooms a delivery window through which the shucked stock is passed to the packing room. Provision shall be made for storing the employees' outer garments, aprons, gloves, etc., in a separate room.
Note: In special instances where shucking is done on a small scale for local retail sales, shucking and packing may be permitted in a single room if approved by the Department of Health Services. This single room and all operations shall conform to all requirements of these regulations except that of separate shucking and packing rooms. "Limited" certificates shall be issued in these instances and all containers of shucked shellfish shall be clearly labeled or marked with words "Limited Certificate" and the appropriate certificate number.
1235.3 Floors
The floors of all rooms in which shellfish are stored, shucked, washed, packed or otherwise processed shall be constructed of concrete or other equally impervious material, graded to drain quickly, free from cracks or uneven surfaces that might interfere with proper cleaning or drainage, and maintained in clean and satisfactory condition.
1235.4 Walls and Ceilings
Walls and ceilings shall be maintained in a smooth, clean, washable, light-colored conditions. They shall be impervious to moisture and shall be kept in good repair. Walls contiguous to benches shall, to a height of 2 feet (610 mm) above the bench top, be of smooth concrete, metal or equally nonabsorbent material.
1235.5 Screening
The plant shall have all openings effectively screened, unless other effective means are provided to prevent the entrance of flies and other insects.
1235.6 Light
Ample light to work by shall be provided in all working rooms. A light intensity of not less than 10 footcandles (108 lux) shall be maintained on all working surfaces when workers are at their working positions.
1235.7 Ventilation
Adequate ventilation shall be provided to prevent condensation on ceilings or other surfaces.
1235.8 Toilet Facilities
Every shellfish culling, shucking, packing or repacking plant shall be provided with clean and adequate toilet facilities conveniently located. No toilet room shall be used for the storage of garments, food products, containers or equipment. Construction and maintenance of toilets shall comply with all local and state regulations.
1235.9 Handwashing Facilities
An adequate number of lavatories shall be provided at locations convenient to toilet rooms and shellfish handling operations, including running hot and cold water, soap and individual disposal towels. The use of a common towel is prohibited. All employees shall wash their hands thoroughly with running water and soap on beginning work and after each visit to the toilet. Signs to this effect shall be posted in conspicuous places in the plant and in the toilet rooms.
1235.10 Sewers and Drains
Sewage and other liquid wastes shall be discharged into public sewers wherever possible. Where private sewage or waste disposal systems must be utilized, they shall be constructed in accordance with state and local regulations pertaining thereto. Plant waste systems shall be properly trapped and vented. Waste liquids shall be disposed of in a manner that will not adversely affect the quality of the water in which shellfish are grown or stored. Waste lines from washing machines shall have suitable protection against the possibility of sewage or wastes entering these machines.
1235.11 Water Supply
Shucking, packing or repacking plants shall be provided with an ample supply of water under adequate pressure from a source approved by the Department of Health Services. The supply shall be accessible to all parts of the plant, adequate in quantity, and of a safe sanitary quality. No cross connections with unapproved supplies or other possible sources of contamination shall be permitted.

Related Code Sections

1235.11 Interior Environment, Water Supply
by the Department of Health Services. The supply shall be accessible to all parts of the plant, adequate in quantity, and of a safe sanitary quality. No cross ...
1235.10 Interior Environment, Sewers and Drains
be utilized, they shall be constructed in accordance with state and local regulations pertaining thereto. Plant waste systems shall be properly trapped ...