• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

P2902.3.6 Double-Check Backflow Prevention Assemblies

Residential Code 2018 of Kansas > 29 Water Supply and Distribution > P2902 Protection of Potable Water Supply > P2902.3 Backflow Protection > P2902.3.6 Double-Check Backflow Prevention Assemblies
JUMP TO FULL CODE CHAPTER
Double-check backflow prevention assemblies shall conform to ASSE 1015, CSA B64.5, CSA B64.5.1 or AWWA C510. Double-check detector fire protection backflow prevention assemblies shall conform to ASSE 1048. These assemblies shall be capable of operating under continuous pressure conditions.

Related Code Sections


608.14.7 Water Supply and Distribution, Double Check Backflow Prevention Assemblies
Double check backflow prevention assemblies shall conform to ASSE 1015, CSA B64.5, CSA B64.5.1 or AWWA C510. Double check detector fire protection ...
Plumbing Code 2018 of Kansas > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.14 Backflow Protection > 608.14.7 Double Check Backflow Prevention Assemblies
P2902.3.6 Water Supply and Distribution, Double-Check Backflow Prevention Assemblies
Double-check backflow prevention assemblies shall conform to ASSE 1015, CSA B64.5, CSA B64.5.1 or AWWA C510. Double-check detector fire protection ...
Residential Code 2018 of Kansas > 29 Water Supply and Distribution > P2902 Protection of Potable Water Supply > P2902.3 Backflow Protection > P2902.3.6 Double-Check Backflow Prevention Assemblies
P2503.8 Plumbing Administration, Inspection and Testing of Backflow Prevention Devices
, double check detector and pressure vacuum breaker backflow preventer assemblies shall be tested at the time of installation, immediately after repairs ...
Residential Code 2018 of Kansas > 25 Plumbing Administration > P2503 Inspection and Tests > P2503.8 Inspection and Testing of Backflow Prevention Devices
608.14 Water Supply and Distribution, Backflow Protection
prevention assemblies shall conform to ASSE 1015, CSA B64.5, CSA B64.5.1 or AWWA C510. Double check detector fire protection backflow prevention ...
Plumbing Code 2018 of Kansas > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.14 Backflow Protection
P2503.8.2 Plumbing Administration, Testing
Reduced pressure principle, double check, double check detector and pressure vacuum breaker backflow preventer assemblies shall be tested at the time ...
Residential Code 2018 of Kansas > 25 Plumbing Administration > P2503 Inspection and Tests > P2503.8 Inspection and Testing of Backflow Prevention Devices > P2503.8.2 Testing
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING