H601.8 Dosing Tanks
JUMP TO FULL CODE CHAPTER
Where the quantity of sewage
exceeds the amount that is permitted to be disposed in 500
lineal feet (152.4 m) of leach line, a dosing tank shall be
used. Dosing tanks shall be equipped with an automatic
siphon or pump that discharges the tank once every 3 or 4
hours. The tank shall have a capacity equal to 60 to 75
percent of the interior capacity of the pipe to be dosed at
one time. Where the total length of pipe exceeds 1000 lineal
feet (304.8 m), the dosing tank shall be provided with two
siphons or pumps dosing alternately and each serving one-half
of the leach field.
Related Code Sections
H601.8 Private Sewage Disposal Systems, Dosing Tanks
Where the quantity of sewage
exceeds the amount that is permitted to be disposed of in 500
lineal feet (152.4 m) of leach line, a dosing tank shall ...
California Plumbing Code 2019 > H Private Sewage Disposal Systems > H601.0 Disposal Fields > H601.8 Dosing Tanks
H601.8 Private Sewage Disposal Systems, Dosing Tanks
Where the quantity of sewage
exceeds the amount that is permitted to be disposed in 500
lineal feet (152.4 m) of leach line, a dosing tank shall ...
California Plumbing Code 2016 > H Private Sewage Disposal Systems > H601.0 Disposal Fields > H601.8 Dosing Tanks
1224.34.2.5 Interior Environment, Dose Administration Area
Provide a dose administration area that is immediately accessible to the preparation area. Since as much as several hours may elapse for the dose ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.34 Nuclear Medicine > 1224.34.2 Support Areas for Nuclear Medicine Services > 1224.34.2.5 Dose Administration Area
1226.5.12.4.2 Interior Environment, Dose Administration Area
Refer to Section 1224.34.2.5 ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1226 [OSHPD 3] Clinics > 1226.5 Outpatient Clinical Services of a Hospital > 1226.5.12 Nuclear Medicine > 1226.5.12.4 Support Areas for Nuclear Medicine Services > 1226.5.12.4.2 Dose Administration Area
1224.34.2 Interior Environment, Support Areas for Nuclear Medicine Services
Provide a dose administration area that is immediately accessible to the preparation ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.34 Nuclear Medicine > 1224.34.2 Support Areas for Nuclear Medicine Services