  1. Contain a minimum of 50 square feet (4.7 m2) of floor area per inmate for a single-bed unit; a minimum of 70 square feet (7 m2) for a double-bed unit; and a minimum of 90 square feet (9.3 m2) for triple-bed unit and have a minimum ceiling height of 8 feet (2438 mm);
  2. Be designed for no more than 64 inmates and no fewer than four inmates;
  3. Provide access to water closets separate from the wash basin and drinking fountains as specified in Section 1231.3; and
  4. In other than Type I facilities, provide storage space for personal items and clothing for each occupant.