• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

465.6 Doors, Interlocks, and Warning Systems

2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 465 Control of Radiation Hazards > 465.6 Doors, Interlocks, and Warning Systems
JUMP TO FULL CODE CHAPTER

465.6.1

A licensee shall control access to the teletherapy room by a door at each entrance.

465.6.2

A licensee shall equip each entrance to the teletherapy room with an electrical interlock system that shall:

  1. Prevent the operator from turning on the primary beam of radiation unless each treatment room entrance door is closed;
  2. Turn off the beam of radiation immediately when an entrance door is opened; and
  3. Prevent the primary beam of radiation from being turned on following an interlock interruption until all treatment room entrance doors are closed and the beam on-off control is reset at the console.

465.6.3

A licensee shall equip each entrance to the teletherapy room with a conspicuously visible beam condition indicator light.

Related Code Sections


465.6 Special Detailed Requirements Based on Use and Occupancy, Doors, Interlocks, and Warning Systems
A licensee shall equip each entrance to the teletherapy room with an electrical interlock system that shall ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 465 Control of Radiation Hazards > 465.6 Doors, Interlocks, and Warning Systems
465.6 Special Detailed Requirements Based on Use and Occupancy, Doors, Interlocks, and Warning Systems
A licensee shall equip each entrance to the teletherapy room with an electrical interlock system that shall ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 465 Control of Radiation Hazards > 465.6 Doors, Interlocks, and Warning Systems
465.6 Special Detailed Requirements Based on Occupancy and Use, Doors, Interlocks, and Warning Systems
A licensee shall equip each entrance to the teletherapy room with an electrical interlock system that shall ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 465 Control of Radiation Hazards > 465.6 Doors, Interlocks, and Warning Systems
465.6.1 Special Detailed Requirements Based on Occupancy and Use,
A licensee shall control access to the teletherapy room by a door at each entrance ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 465 Control of Radiation Hazards > 465.6 Doors, Interlocks, and Warning Systems > 465.6.1
465.6.3 Special Detailed Requirements Based on Use and Occupancy,
A licensee shall equip each entrance to the teletherapy room with a conspicuously visible beam condition indicator light ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 465 Control of Radiation Hazards > 465.6 Doors, Interlocks, and Warning Systems > 465.6.3
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE