// CODE SNIPPET
1124A.8 Doorjamb Marking
JUMP TO FULL CODE CHAPTER
The floor level at all elevator hoistway entrances shall be designated by raised characters provided on both jambs. Characters shall be 2 inches (50.8 mm) in height located 48 inches (1219 mm) minimum above the finish floor, measured from the baseline of the lowest Braille cells, and 60 inches (1524 mm) maximum above the finish floor, measured from the baseline of the highest line of raised characters.
On the main entry level, a raised five-pointed star shall be placed to the left of the raised character. The outside diameter of the star shall be 2 inches (50.8 mm) and all points shall be of equal length. The raised characters and the star shall be white on a black background. Contracted Grade 2 Braille, conforming to Section 1143A.7, shall be placed below the corresponding raised characters and the star. The Braille translation for the star shall state "MAIN". The raised characters shall comply with Section 1143A.6. (See Figure 11A-7C.)
Related Code Sections
1124A.8 Housing Accessibility, Doorjamb Marking
The floor level at all elevator hoistway entrances shall be designated by raised characters provided on both jambs. Characters shall be 2 inches (50.8 ...
California Building Code 2016 (Vol 1 & 2) > 11A Housing Accessibility > 1124A Elevators and Platform (Wheelchair) Lifts > 1124A.8 Doorjamb Marking
1124A.8 Housing Accessibility, Doorjamb Marking
The floor level at all elevator
hoistway entrances shall be designated by raised characters
provided on both jambs. Characters shall be 2 inches (50.8 ...
California Building Code 2019 (Vol 1 & 2) > 11A Housing Accessibility > 1124A Elevators and Platform (Wheelchair) Lifts > 1124A.8 Doorjamb Marking
10.6.10.1 Fundamentals, Marking
Batteries shall be marked with the month and year of manufacture using the month/year format ...
National Fire Alarm and Signaling Code 2016 of California > 10 Fundamentals > 10.6 Power Supplies > 10.6.10* Storage Batteries > 10.6.10.1 Marking
110.21 General, Marking
The manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product can be identified shall ...
California Electrical Code 2019 > 1 General > 110 Requirements for Electrical Installations > 110.21 Marking
11B-502.3.3 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Marking
Access aisles shall be marked with a blue painted borderline around their perimeter. The area within the blue borderlines shall be marked ...
California Building Code 2016 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-502 Parking Spaces > 11B-502.3 Access Aisle > 11B-502.3.3 Marking