• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

404.2.9 Door Surface

Minnesota Accessibility Code 2015 > 4 Accessible Routes > 404 Doors and Doorways > 404.2 Manual Doors > 404.2.9 Door Surface
JUMP TO FULL CODE CHAPTER
ILLUSTRATION
Door surfaces within 10 inches (255 mm) of the floor, measured vertically, shall be a smooth surface on the push side extending the full width of the door. Parts creating horizontal or vertical joints in such surface shall be within 1/16 inch (1.6 mm) of the same plane as the other. Cavities created by added kick plates shall be capped.
Exceptions:
  1. Sliding doors shall not be required to comply with Section 404.2.9.
  2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at no less than 60 degrees from the horizontal shall not be required to comply with the 10-inch (255 mm) bottom rail height requirement.
  3. Doors that do not extend to within 10 inches (255 mm) of the floor shall not be required to comply with Section 404.2.9.

Related Code Sections


404.2.9 Accessible Routes, Door Surface
Door surfaces within 10 inches (255 mm) of the floor, measured vertically, shall be a smooth surface on the push side extending the full width ...
Minnesota Accessibility Code 2015 > 4 Accessible Routes > 404 Doors and Doorways > 404.2 Manual Doors > 404.2.9 Door Surface
404.2.9 Accessible Routes, Door Surface
Door surfaces within 10 inches (255 mm) of the floor, measured vertically, shall be a smooth surface on the push side extending the full width ...
Accessible and Usable Buildings and Facilities 2009 of Minnesota > 4 Accessible Routes > 404 Doors and Doorways > 404.2 Manual Doors > 404.2.9 Door Surface
2409.3.2 Glass and Glazing, Surface Area
The glass in glass elevator car doors shall be not less than 60 percent of the total visible door panel surface area as seen from the car side ...
Minnesota Building Code 2015 > 24 Glass and Glazing > 2409 Glass in Elevator Hoistways and Elevator Cars > 2409.3 Glass in Elevator Cars > 2409.3.2 Surface Area
2409.4.2 Glass and Glazing, Surface Area
The glass in glass elevator car doors shall be not less than 60 percent of the total visible door panel surface area as seen from the car side ...
2020 Minnesota Building Code > 24 Glass and Glazing > 2409 Glass in Walkways, Elevator Hoistways and Elevator Cars > 2409.4 Glass in Elevator Cars > 2409.4.2 Surface Area
804.5.5 Special Rooms and Spaces, Oven
Side-hinged door ovens shall have a work surface complying with Section 804.3 ...
Minnesota Accessibility Code 2015 > 8 Special Rooms and Spaces > 804 Kitchens and Kitchenettes > 804.5 Appliances > 804.5.5 Oven
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE