453.26.3 Door Requirements
JUMP TO FULL CODE CHAPTER
The door shall have only a push plate exposed on the interior of the room.
The door shall swing out of the room and shall be equipped with a fully concealed track-type closer.
A vision panel shall be provided in the door, and it shall be no larger than 144 square inches (0.093 m2). The view panel shall consist of a clear 1/4-inch-thick (6 mm) unbreakable plastic panel flush with the inside face of the door on the inside of the room. The panel shall be positioned in the door so that a staff member may continuously keep the student under surveillance.
The door frame and jamb/head reveal on the inside shall be minimal. If provided, a flat metal threshold shall be used.
Related Code Sections
453.26.3 Special Detailed Requirements Based on Use and Occupancy, Door Requirements
The door shall have only a push plate exposed on the interior of the room ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 453 State Requirements for Educational Facilities > 453.26 Time-Out Rooms > 453.26.3 Door Requirements
453.26.3 Special Detailed Requirements Based on Use and Occupancy, Door Requirements
The door shall have only a push plate exposed on the interior of the room ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 453 State Requirements for Educational Facilities > 453.26 Time-Out Rooms > 453.26.3 Door Requirements
453.26.3 Special Detailed Requirements Based on Occupancy and Use, Door Requirements
The door shall have only a push plate exposed on the interior of the room ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 453 State Requirements for Educational Facilities > 453.26 Time-Out Rooms > 453.26.3 Door Requirements
407.3 Accessible Routes, Elevator Door Requirements
by an object or person. EXCEPTION: Existing elevators with manually operated doors shall not be required to comply with 407.3.3 ...
2017 FBC - Accessibility, 6th edition > 4 Accessible Routes > 407 Elevators > 407.3 Elevator Door Requirements
407.3 Accessible Routes, Elevator Door Requirements
by an object or person. EXCEPTION: Existing elevators with manually operated doors shall not be required to comply with 407.3.3 ...
2020 FBC - Accessibility, 7th edition > 4 Accessible Routes > 407 Elevators > 407.3 Elevator Door Requirements