1106.2.1 Door Openings
JUMP TO FULL CODE CHAPTER
Where one-hour fire-resistant construction is required, openings shall be protected by listed fire doors, insulated steel doors, 13/8-inch thick (35 mm) or 13/4-inch thick (45 mm) solid wood doors, or fixed wired glass set in steel frames. Doors shall be self-closing or automatic-closing by smoke detection.
Related Code Sections
1106.2.1 Construction Requirements for Existing Buildings, Door Openings
Where one-hour fire-resistant construction is required, openings shall be protected by listed fire doors, insulated steel doors, 1 3 / 8 -inch thick ...
Minnesota Fire Code 2015 > 11 Construction Requirements for Existing Buildings > 1106 Separation of Occupancies and Hazardous Areas > 1106.2 Occupancy Separations > 1106.2.1 Door Openings
1008.1.3 Means of Egress, Door Opening Force
The force for pushing or pulling open interior swinging egress doors, other than fire doors , shall not exceed 5 pounds (22 N). For other swinging ...
Minnesota Building Code 2015 > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.3 Door Opening Force
1008.1.3 Means of Egress, Door Opening Force
The force for pushing or pulling open interior swinging egress doors, other than fire doors , shall not exceed 5 pounds (22 N). For other swinging ...
Minnesota Fire Code 2015 > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.3 Door Opening Force
1010.1.3 Means of Egress, Door Opening Force
The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do ...
2020 Minnesota State Fire Code > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.3 Door Opening Force
1010.1.3 Means of Egress, Door Opening Force
The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do ...
2020 Minnesota Building Code > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.3 Door Opening Force