• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1106.2.1 Door Openings

Minnesota Fire Code 2015 > 11 Construction Requirements for Existing Buildings > 1106 Separation of Occupancies and Hazardous Areas > 1106.2 Occupancy Separations > 1106.2.1 Door Openings
JUMP TO FULL CODE CHAPTER
Where one-hour fire-resistant construction is required, openings shall be protected by listed fire doors, insulated steel doors, 13/8-inch thick (35 mm) or 13/4-inch thick (45 mm) solid wood doors, or fixed wired glass set in steel frames. Doors shall be self-closing or automatic-closing by smoke detection.

Related Code Sections


1106.2.1 Construction Requirements for Existing Buildings, Door Openings
Where one-hour fire-resistant construction is required, openings shall be protected by listed fire doors, insulated steel doors, 1 3 / 8 -inch thick ...
Minnesota Fire Code 2015 > 11 Construction Requirements for Existing Buildings > 1106 Separation of Occupancies and Hazardous Areas > 1106.2 Occupancy Separations > 1106.2.1 Door Openings
1008.1.3 Means of Egress, Door Opening Force
The force for pushing or pulling open interior swinging egress doors, other than fire doors , shall not exceed 5 pounds (22 N). For other swinging ...
Minnesota Building Code 2015 > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.3 Door Opening Force
1008.1.3 Means of Egress, Door Opening Force
The force for pushing or pulling open interior swinging egress doors, other than fire doors , shall not exceed 5 pounds (22 N). For other swinging ...
Minnesota Fire Code 2015 > 10 Means of Egress > 1008 Doors, Gates and Turnstiles > 1008.1 Doors > 1008.1.3 Door Opening Force
1010.1.3 Means of Egress, Door Opening Force
The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do ...
2020 Minnesota State Fire Code > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.3 Door Opening Force
1010.1.3 Means of Egress, Door Opening Force
The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not exceed 5 pounds (22 N). These forces do ...
2020 Minnesota Building Code > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.1 Doors > 1010.1.3 Door Opening Force
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE