Both jambs of all elevator hoistway entrances shall have raised and Braille floor designation jambs that are visible from within the car and the elevator lobby.
28.5.1
The centerline of the characters shall be 60 inches (60" = 1524mm) above finish floor. See Fig. 28a.
28.5.2
Such characters shall be two inches (2" = 51mm) high and on a contrasting color background.
28.5.3
Permanently applied plates are acceptable if they are secured to the jambs.