404.2.8.1 Door Closers and Gate Closers
JUMP TO FULL CODE CHAPTER
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Related Code Sections
404.2.8.1 Accessible Routes, Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 ...
2010 ADA Standards > 4 Accessible Routes > 404 Doors, Doorways, and Gates > 404.2 Manual Doors, Doorways, and Manual Gates > 404.2.8 Closing Speed > 404.2.8.1 Door Closers and Gate Closers
404.2.3 Accessible Routes, Clear Width
be permitted for the latch side stop.
Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the finish floor or ground ...
2010 ADA Standards > 4 Accessible Routes > 404 Doors, Doorways, and Gates > 404.2 Manual Doors, Doorways, and Manual Gates > 404.2.3 Clear Width
410.6 Accessible Routes, Doors and Gates
Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum. End doors ...
206.5 Scoping Requirements, Doors, Doorways, and Gates
Doors, doorways, and gates providing user passage shall be provided in accordance with 206.5 ...
2010 ADA Standards > 2 Scoping Requirements > 206 Accessible Routes > 206.5 Doors, Doorways, and Gates
404.2.10 Accessible Routes, Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push ...
2010 ADA Standards > 4 Accessible Routes > 404 Doors, Doorways, and Gates > 404.2 Manual Doors, Doorways, and Manual Gates > 404.2.10 Door and Gate Surfaces