404.2.10 Door and Gate Surfaces
JUMP TO FULL CODE CHAPTER
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch (1.6 mm) of the same plane as the other. Cavities created by added kick plates shall be capped.
EXCEPTIONS:
- Sliding doors shall not be required to comply with 404.2.10.
- Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch (255 mm) bottom smooth surface height requirement.
- Doors and gates that do not extend to within 10 inches (255 mm) of the finish floor or ground shall not be required to comply with 404.2.10.
- Existing doors and gates without smooth surfaces within 10 inches (255 mm) of the finish floor or ground shall not be required to provide smooth surfaces complying with 404.2.10 provided that if added kick plates are installed, cavities created by such kick plates are capped.
Related Code Sections
404.2.10 Accessible Routes, Door and Gate Surfaces
Swinging door and gate surfaces within 10 inches (255 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push ...
2010 ADA Standards > 4 Accessible Routes > 404 Doors, Doorways, and Gates > 404.2 Manual Doors, Doorways, and Manual Gates > 404.2.10 Door and Gate Surfaces
410.6 Accessible Routes, Doors and Gates
Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum. End doors ...
206.5 Scoping Requirements, Doors, Doorways, and Gates
Doors, doorways, and gates providing user passage shall be provided in accordance with 206.5 ...
2010 ADA Standards > 2 Scoping Requirements > 206 Accessible Routes > 206.5 Doors, Doorways, and Gates
404.2.4.3 Accessible Routes, Recessed Doors and Gates
more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate. Advisory 404.2.4.3 Recessed Doors ...
2010 ADA Standards > 4 Accessible Routes > 404 Doors, Doorways, and Gates > 404.2 Manual Doors, Doorways, and Manual Gates > 404.2.4 Maneuvering Clearances > 404.2.4.3 Recessed Doors and Gates
404.2.7 Accessible Routes, Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4. Operable parts of such hardware shall ...
2010 ADA Standards > 4 Accessible Routes > 404 Doors, Doorways, and Gates > 404.2 Manual Doors, Doorways, and Manual Gates > 404.2.7 Door and Gate Hardware