Fire doors shall have a minimum opening force allowable by the appropriate administrative authority.  The force for pushing or pulling open a door or gate other than fire doors shall be as follows:
  1. Interior hinged doors and gates:  5 pounds (22.2 N) maximum.
  2. Sliding or folding doors:  5 pounds (22.2 N) maximum.
These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door or gate in a closed position.
Advisory 404.2.9 Door and Gate Opening Force.  The maximum force pertains to the continuous application of force necessary to fully open a door, not the initial force needed to overcome the inertia of the door.  It does not apply to the force required to retract bolts or to disengage other devices used to keep the door in a closed position.

Related Code Sections

404.2.9 Accessible Routes, Door and Gate Opening Force
the door or gate in a closed position. Advisory 404.2.9 Door and Gate Opening Force.  The maximum force pertains to the continuous application ...
410.6 Accessible Routes, Doors and Gates
Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum. End doors ...
409.3 Accessible Routes, Elevator Doors
or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1). Power operated doors and gates shall remain open for 20 seconds ...
404.3.1 Accessible Routes, Clear Width
Doorways shall provide a clear opening of 32 inches (815 mm) minimum in power-on and power-off mode.  The minimum clear width for automatic door ...
404.2.8 Accessible Routes, Closing Speed
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position ...