• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Article 8 Documents and Records

California Administrative Code 2019 > 4 Administrative Regulations for the Division of the State Architect—Structural Safety (DSA-SS) > 8 Documents and Records
JUMP TO FULL CODE CHAPTER

4-350 Records

The records retained by DSA pertaining to the supervision of the construction of school buildings by DSA are public documents and are open to inspection during office hours. Documents shall not be taken from the custody of DSA except as required by law.

Examination reports prepared under the provisions of Sections 17313 and 81162 of the Act (See Section 4-345) are considered to be the property of the school board. Inquiries regarding examination reports shall be referred to the school board concerned.

Authority: Education Code Sections 17310 and 81142.

Reference: Education Code Sections 17295, 17315, 81133 and 81147; and Health and Safety Code Sections 19850 through 19853.

HISTORY:

  1. (OSA/SS 1/92) Regular order by the Office of the State Architect/Structural Safety Section to amend Section 4-350, Part 1, Title 24, C.C.R. Filed with the Secretary of State on December 15, 1992; effective July 1, 1993. Approved by the California Building Standards Commission on December 9, 1992.

4-351 Location of Records

A file of school building plans, specifications and documents for currently active school projects in each of four regions of the state is maintained in the respective DSA regional office: Oakland (Region 1), Sacramento (Region II), Los Angeles (Region III) and San Diego (Region IV). Completed or certified project records including plans and specifications are stored in the State Records Center in Sacramento or in electronic format at the regional offices.

Authority: Education Code Sections 17310 and 81142.

Reference: Education Code Sections 17295, 17299, 17309, 81133, 81135 and 81141.

HISTORY:

  1. (OSA/SS 1/92) Regular order by the Office of the State Architect/Structural Safety Section to amend Section 4-351, Part 1, Title 24, C.C.R. Filed with the Secretary of State on December 15, 1992; effective July 1, 1993. Approved by the California Building Standards Commission on December 9, 1992.

4-352 Submission of Documents

  1. Application. Applications for approval of plans and specifications shall be submitted to the DSA regional office serving the project location unless specific approval for submittal elsewhere is given by the State Architect. Processing shall be completed by the receiving office but portions of the work may be reassigned.
  2. Construction documents. All documents such as notices in accordance with Sections 4-331 and 4-332, qualification records in accordance with Sections 4-333 and 4-341, test reports in accordance with Section 4-335, special inspection reports in accordance with Section 4-335, verified reports in accordance with Section 4-336, and semimonthly reports in accordance with Section 4-337 shall be submitted to the appropriate DSA regional office according to location of the project.

Authority: Education Code Sections 17310 and 81142.

Reference: Education Code Sections 17295, 17299, 17309, 81133, 81135 and 81141.

HISTORY:

  1. (OSA/SS 1/92) Regular order by the Office of the State Architect/Structural Safety Section to amend Section 4-352, Part 1, Title 24, C.C.R. Filed with the Secretary of State on December 15, 1992; effective July 1, 1993. Approved by the California Building Standards Commission on December 9, 1992.

Related Code Sections


Article 8 Administrative Regulations for the Division of the State Architect—Structural Safety (DSA-SS), Documents and Records
The records retained by DSA pertaining to the supervision of the construction of school buildings by DSA are public documents and are open ...
California Administrative Code 2019 > 4 Administrative Regulations for the Division of the State Architect—Structural Safety (DSA-SS) > 8 Documents and Records
Article 8 Safety of Construction of Public Schools, Documents and Records
The records retained by DSA pertaining to the supervision of the construction of school buildings by DSA are public documents and are open ...
California Administrative Code 2016 > 1 Safety of Construction of Public Schools > 8 Documents and Records
4-352 Administrative Regulations for the Division of the State Architect—Structural Safety (DSA-SS), Submission of Documents
of the work may be reassigned. Construction documents. All documents such as notices in accordance with Sections 4-331 and 4-332, qualification records ...
California Administrative Code 2019 > 4 Administrative Regulations for the Division of the State Architect—Structural Safety (DSA-SS) > 8 Documents and Records > 4-352 Submission of Documents
3102F.1.4 [SLC] Marine Oil Terminals, Records
and documents. Chronological records and reports of annual inspections, audits and post-event inspections and documentation of equipment or structural ...
California Building Code 2016 (Vol 1 & 2) > 31F [SLC] Marine Oil Terminals > 3102F Audit and Inspection > 3102F.1 General > 3102F.1.4 Records
1307.4 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Documentation
The brazing procedure qualification record and the record of brazer performance qualification shall document filler metal used, cleaning, joint ...
California Plumbing Code 2019 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1307.0 Brazing Procedures > 1307.4 Documentation
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE