Section 808 Diving Equipment
JUMP TO FULL CODE CHAPTER
Manufactured and fabricated diving equipment shall be in accordance with this section. Manufactured and fabricated diving equipment and appurtenances shall not be installed on a Type O pool.
Manufactured diving equipment shall be designed for swimming pool use.
Where manufactured diving equipment is installed, the installation shall be located in the deep area of the pool so as to provide the minimum dimensions as shown in Table 804.1 and shall be installed in accordance with the manufacturer's instructions.
Manufactured diving equipment shall have a permanently affixed label indicating the manufacturer's name and address, the date of manufacture, the minimum diving envelope and the maximum weight limitation.
Diving equipment shall have slip-resistant walking surfaces.
For the application of Table 804.1, Point A shall be the point from which all dimensions of width, length and depth are established for the minimum diving water envelope. If the tip of the diving board or diving platform is located at a distance of WA or greater from the deep end wall and the water depth at that location is equal to or greater than the water depth requirement at Point A, then the point on the water surface directly below the center of the tip of the diving board or diving platform shall be identified as Point A.
Where a pool is designed for use with diving equipment, the location of steps, pool stairs, ladders, underwater benches, special features and other accessory items shall be outside of the minimum diving water envelope as indicated in Figure 322.2.
Stationary diving platforms and diving rocks built on-site shall be permitted to be flush with the wall and shall be located in the diving area of the pool. Point A shall be in front of the wall at the platform or diving rock centerline.
The forward tip of manufactured or fabricated diving equipment shall be located directly above Point A as defined by Section 808.6.
The maximum elevation of a diving board above the design waterline shall be in accordance with the manufacturer's instructions.
Manufactured diving equipment installation and use instructions shall be provided by the diving equipment manufacturer and shall specify the minimum water dimensions required for each diving board and diving stand combination. The board manufacturer shall indicate the water envelope type by dimensionally relating their products to Point A on the water envelopes as shown in Figure 804.1 and Table 804.1. The board manufacturer shall specify which boards fit on the design pool geometry types as indicated in Table 804.1.
The height of a stationary diving platform or a diving rock above the design waterline shall not exceed the dimensions in Table 808.12.
TABLE 808.12
DIVING PLATFORM OR APPURTENANCE
HEIGHT ABOVE DESIGN WATERLINE
POOL TYPE | HEIGHT INCHES |
I | 42 |
II | 42 |
II | 50 |
IV | 60 |
V | 69 |
For SI: 1 inch = 25.4 mm.
The diving equipment manufacturer shall specify the minimum headroom required above the board tip.
Related Code Sections
406.6 Public Swimming Pools, Diving Equipment
Diving equipment shall be installed in accordance with the manufacturer's specifications ...
Georgia State Minimum Standard Swimming Pool and Spa Code > 4 Public Swimming Pools > 406 Decks and Deck Equipment > 406.6 Diving Equipment
406.8 Public Swimming Pools, Diving Equipment
Diving equipment shall be installed in accordance with the manufacturer's specifications ...
Georgia State Minimum Standard Swimming Pool and Spa Code > 4 Public Swimming Pools > 406 Decks and Deck Equipment > 406.8 Diving Equipment
Section 808 Permanent Inground Residential Swimming Pools, Diving Equipment
Manufactured and fabricated diving equipment shall be in accordance with this section. Manufactured and fabricated diving equipment and appurtenances ...
Georgia State Minimum Standard Swimming Pool and Spa Code > 8 Permanent Inground Residential Swimming Pools > 808 Diving Equipment
Section 808 Permanent Inground Residential Swimming Pools, Diving Equipment
Manufactured and fabricated diving equipment shall be in accordance with this section. Manufactured and fabricated diving equipment and appurtenances ...
Georgia State Minimum Standard Swimming Pool and Spa Code > 8 Permanent Inground Residential Swimming Pools > 808 Diving Equipment
402.13 Public Swimming Pools, Ladders for Diving Equipment
Ladders shall be provided with two grab rails or two handrails. There shall be a uniform distance between ladder treads, with a 7-inch (178 mm ...
Georgia State Minimum Standard Swimming Pool and Spa Code > 4 Public Swimming Pools > 402 Diving > 402.13 Ladders for Diving Equipment