Where more than one exit, or access to more than one exit, is required, the means of egress shall be configured such that the loss of any one exit, or access to one exit, shall not reduce the available capacity or width to less than 50 percent of the required capacity or width.

Related Code Sections

1005.5 Means of Egress, Distribution of Minimum Width and Required Capacity
, or access to one exit, shall not reduce the available capacity or width to less than 50 percent of the required capacity or width ...
1005.5 Means of Egress, Distribution of Minimum Width and Required Capacity
, or access to one exit, shall not reduce the available capacity or width to less than 50 percent of the required capacity or width ...
1012.5.1 Means of Egress, Width and Capacity
The minimum width and required capacity of a means of egress ramp shall be not less than that required for corridors by Section 1020.2. The clear ...
1012.5.1 Means of Egress, Width and Capacity
The minimum width and required capacity of a means of egress ramp shall be not less than that required for corridors by Section 1020.3. The clear ...
1024.2 Means of Egress, Width and Capacity
The required capacity of exit passageways shall be determined as specified in Section 1005.1 but the minimum width shall be not less than 44 inches ...