11B-206.2.3.2 Distance to Elevators
JUMP TO FULL CODE CHAPTER
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp, elevator or lift shall be provided within 200 feet (60,960 mm) of travel of each stair and each escalator. In existing buildings that exceed 10,000 square feet (929 m2) on any floor and in which elevators are required by Section 11B-206.2.3, whenever a newly constructed means of vertical access is provided via stairs or an escalator, an accessible means of vertical access via ramp, elevator or lift shall be provided within 200 feet (60,960 mm) of travel of each new stair or escalator.
Exception: Stairs used solely for emergency egress.
Related Code Sections
11B-206.2.3.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Distance to Elevators
In new construction of buildings where elevators are required by Section 11B -206.2.3, and which exceed 10,000 square feet (929 m 2 ) on any floor ...
California Building Code 2016 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-206 Accessible Routes > 11B-206.2 Where Required > 11B-206.2.3 Multi-Story Buildings and Facilities > 11B-206.2.3.2 Distance to Elevators
11B-206.2.3.2 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Distance to Elevators
In new construction
of buildings where elevators are required by Section
11B-206.2.3, and which exceed 10,000 square feet
(929 m 2 ) on any floor ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-206 Accessible Routes > 11B-206.2 Where Required > 11B-206.2.3 Multistory Buildings and Facilities > 11B-206.2.3.2 Distance to Elevators
607.1 Building Services and Systems, Emergency Operation
Existing elevators with a travel distance of 25 feet (7620 mm) or more shall comply with the requirements in Chapter 11. New elevators shall ...
California Fire Code 2016 > 6 Building Services and Systems > 607 Elevator Operation, Maintenance and Fire Service Keys > 607.1 Emergency Operation
606.1 Building Services and Systems, Emergency Operation
Existing elevators with a travel distance of 25 feet (7620 mm) or more shall comply with the requirements in Chapter 11. New elevators shall ...
California Fire Code 2019 > 6 Building Services and Systems > 606 Elevator Operation, Maintenance and Fire Service Keys > 606.1 Emergency Operation
8.6.4.1.3.2* Installation Requirements,
Under saw-toothed roofs, sprinklers at the highest elevation shall not exceed a distance of 36 in. (900 mm) measured down the slope from the peak ...
Standard for the Installation of Sprinkler Systems 2016 of California > 8 Installation Requirements > 8.6 Standard Pendent and Upright Spray Sprinklers > 8.6.4 Deflector Position (Standard Pendent and Upright Spray Sprinklers) > 8.6.4.1 Distance Below Ceilings > 8.6.4.1.3 Peaked Roofs and Ceilings > 8.6.4.1.3.2*