• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

912.2.2 Distance From Hydrant

NYC Fire Code 2014 > 9 Fire Protection Systems > 912 Fire Department Connections > 912.2 Location > 912.2.2 Distance From Hydrant
JUMP TO FULL CODE CHAPTER
Fire department connections shall be located at a distance from the nearest fire hydrant as required by the Building Code.

Related Code Sections


§27-963 Fire Alarm, Detection and Extinguishing Equipment, Direct Connection of Sprinklers to the Public Water System
be accompanied by a statement from the bureau of water supply of the department of environmental protection, stating the size of street main or mains, distance ...
NYC 1968 Code (Vol I) > 17 Fire Alarm, Detection and Extinguishing Equipment > 4 Automatic Sprinkler Requirements > §27-963 Direct Connection of Sprinklers to the Public Water System
§27-933 Fire Alarm, Detection and Extinguishing Equipment, Yard Hydrant Systems Required
hydrants installed so that the entire area may be reached by two hundred fifty feet of hose from a yard hydrant or a street hydrant. Single hydrant ...
NYC 1968 Code (Vol I) > 17 Fire Alarm, Detection and Extinguishing Equipment > 3 Standpipe Requirements > §27-933 Yard Hydrant Systems Required
Article 17 Standpipe Systems [PDF] (page 15)
of subdivision (a) of section C26-1407.0. The maximum distance between hydrants shall be two hundred fifty feet. Hydrants and sufficient rubber lined hose ...
NYC 1938 Code [PDF] > 17 Standpipe Systems
Article 16 Sprinkler Systems [PDF] (page 7)
per minute at a two and one-half inch outlet from a hydrant at the street level within two hundred-fifty feet of the structure. The hydrant test shall ...
NYC 1938 Code [PDF] > 16 Sprinkler Systems
3303.7.1.1 Safeguards During Construction or Demolition, Large Footprint Construction
along every 250 feet (76 200 mm) of building perimeter, and with no hydrant more than 50 feet (15 240 mm) from the exterior wall ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.7 Fire Prevention and Fire Protection > 3303.7.1 Water Supply > 3303.7.1.1 Large Footprint Construction
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE