202.4.1 Disproportionate Cost
JUMP TO FULL CODE CHAPTER
Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when the cost exceeds 20% of the cost of the alteration to the primary function area. Costs that may be counted as expenditures required to provide an accessible path of travel may include: (i) costs associated with providing an accessible entrance and an accessible route to the altered area; (ii) costs associated with making restrooms accessible, such as installing grab bars, enlarging toilet stalls, insulating pipes, or installing accessible faucet controls; (iii) costs associated with providing accessible telephones, such as relocating the telephone to an accessible height, installing amplification devices, or installing a text telephone (TTY); (iv) costs associated with relocating an inaccessible drinking fountain.
Related Code Sections
202.4.1 Scoping Requirements, Disproportionate Cost
Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when ...
2017 FBC - Accessibility, 6th edition > 2 Scoping Requirements > 202 Existing Buildings and Facilities > 202.4 Alterations Affecting Primary Function Areas > 202.4.1 Disproportionate Cost
202.4.1 Scoping Requirements, Disproportionate Cost
Alterations made to provide an accessible path of travel to the altered area will be deemed disproportionate to the overall alteration when ...
2020 FBC - Accessibility, 7th edition > 2 Scoping Requirements > 202 Existing Buildings and Facilities > 202.4 Alterations Affecting Primary Function Areas > 202.4.1 Disproportionate Cost
202.4.3 Scoping Requirements, Series of Smaller Alterations
period shall be considered in determining whether the cost of making that path of travel accessible is disproportionate ...
2020 FBC - Accessibility, 7th edition > 2 Scoping Requirements > 202 Existing Buildings and Facilities > 202.4 Alterations Affecting Primary Function Areas > 202.4.3 Series of Smaller Alterations
202.4 Scoping Requirements, Alterations Affecting Primary Function Areas
such alterations are disproportionate to the overall alterations in terms of cost pursuant to 202.4.1. Alterations to windows, hardware, controls, electrical ...
2020 FBC - Accessibility, 7th edition > 2 Scoping Requirements > 202 Existing Buildings and Facilities > 202.4 Alterations Affecting Primary Function Areas
202.4 Scoping Requirements, Alterations Affecting Primary Function Areas
such alterations are disproportionate to the overall alterations in terms of cost pursuant to 202.4.1. Alterations to windows, hardware, controls, electrical ...
2017 FBC - Accessibility, 6th edition > 2 Scoping Requirements > 202 Existing Buildings and Facilities > 202.4 Alterations Affecting Primary Function Areas