3304.10 Disposal of Explosives
JUMP TO FULL CODE CHAPTER
The department shall be notified immediately when explosives are determined to be deteriorated or leaking or otherwise unstable or in need of disposal.
When an explosive has deteriorated to an extent that it is in an unstable or dangerous condition, or when a liquid has leaked from an explosive, the person in possession of such explosives shall immediately contact the manufacturer to obtain handling and disposal instructions.
Unused explosives may be destroyed at the job site only when approved. When approved, such destruction of explosives shall be conducted by a qualified person at an approved location under the supervision of department representatives. It shall be unlawful to dispose of explosives by burning.
Explosives that fail to detonate during blasting operations shall be handled in accordance with FC3307.15 and other approved procedures until the blaster has determined the proper method for disposal in consultation with the department.
High explosives in storage at a job site at the completion of blasting operations, or which are not otherwise to be used at the job site, shall be removed from the job site and transported to a vendor's facility. The vendor may store and supply for use unopened cases of high explosives. The vendor may not supply open cases of high explosives for use unless the explosives are packaged in an approved manner, and their condition certified in writing in an approved manner by the magazine keeper previously responsible for their storage.
Related Code Sections
3303.15.3 Safeguards During Construction or Demolition, Disposal
Collected concrete washout water shall be transported off site for treatment and disposal or contained on site until completely evaporated. Any ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.15 Concrete Washout Water > 3303.15.3 Disposal
3303.15.3 Safeguards During Construction or Demolition, Disposal
Collected concrete washout water shall be transported off site for treatment and disposal or contained on site until completely evaporated. Any ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.15 Concrete Washout Water > 3303.15.3 Disposal
502.9.4 Exhaust Systems, Explosives
, assembly or testing of explosives. Only nonferrous fan blades shall be used for fans located within the ductwork and through which hazardous materials ...
NYC Mechanical Code 2008 > 5 Exhaust Systems > 502 Required Systems > 502.9 Hazardous Materials—Requirements for Specific Materials > 502.9.4 Explosives
502.9.4 Exhaust Systems, Explosives
, assembly or testing of explosives. Only nonferrous fan blades shall be used for fans located within the ductwork and through which hazardous materials ...
NYC Mechanical Code 2014 > 5 Exhaust Systems > 502 Required Systems > 502.9 Hazardous Materials—Requirements for Specific Materials > 502.9.4 Explosives
Section 307 General Regulations, Condensate Disposal
Liquid combustion by-products of condensing appliances shall be collected and discharged to a plumbing fixture or disposal area in accordance ...