• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.152(e) Dispensing Liquids

OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(e) Dispensing Liquids
JUMP TO FULL CODE CHAPTER

1926.152(e)(1)

Areas in which flammable liquids are transferred at one time, in quantities greater than 5 gallons from one tank or container to another tank or container, shall be separated from other operations by 25-feet distance or by construction having a fire resistance of at least 1 hour. Drainage or other means shall be provided to control spills. Adequate natural or mechanical ventilation shall be provided to maintain the concentration of flammable vapor at or below 10 percent of the lower flammable limit.

1926.152(e)(2)

Transfer of Category 1, 2, or 3 flammable liquids from one container to another shall be done only when containers are electrically interconnected (bonded).

1926.152(e)(3)

Flammable liquids shall be drawn from or transferred into vessels, containers, or tanks within a building or outside only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container, or portable tanks, by gravity or pump, through an approved self-closing valve. Transferring by means of air pressure on the container or portable tanks is prohibited.

1926.152(e)(4)

The dispensing units shall be protected against collision damage.

1926.152(e)(5)

Dispensing devices and nozzles for Category 1, 2, or 3 flammable liquids shall be of an approved type.

Related Code Sections


1926.152(e) Fire Protection and Prevention, Dispensing Liquids
Dispensing devices and nozzles for Category 1, 2, or 3 flammable liquids shall be of an approved type ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(e) Dispensing Liquids
1926.152(d)(4) Fire Protection and Prevention,
for transporting and/or dispensing flammable liquids ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(d) Fire Control for Flammable Liquid Storage > 1926.152(d)(4)
1926.152(g)(8) Fire Protection and Prevention,
or dispensing of flammable liquids ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(g) Service and Refueling Areas > 1926.152(g)(8)
1926.152(g) Fire Protection and Prevention, Service and Refueling Areas
areas, where Category 1, 2, or 3 flammable liquids are dispensed, shall be of an approved type for garages, and shall be installed at least 8 feet ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(g) Service and Refueling Areas
1926.152(g)(7) Fire Protection and Prevention,
areas, where Category 1, 2, or 3 flammable liquids are dispensed, shall be of an approved type for garages, and shall be installed at least 8 feet above ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(g) Service and Refueling Areas > 1926.152(g)(7)
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING