Section P2717 Dishwashing Machines

Jump To Full Code Chapter
P2717.1 Protection of Water Supply
The water supply to a dishwasher shall be protected against backflow by an air gap complying with ASME A112.1.3 or A112.1.2 that is installed integrally within the machine or a backflow preventer in accordance with Section P2902.
P2717.2 Sink and Dishwasher
The combined discharge from a dishwasher and a one- or two-compartment sink, with or without a food-waste disposer, shall be served by a trap of not less than 11/2 inches (38 mm) in outside diameter. The dishwasher discharge pipe or tubing shall rise to the underside of the counter and be fastened or otherwise held in that position before connecting to the head of the food-waste disposer or to a wye fitting in the sink tailpiece.

Related Code Sections

Section 409 Fixtures, Faucets and Fixture Fittings, Dishwashing Machines
Commercial dishwashing machines shall conform to ASSE 1004 and NSF 3. Residential dishwashers shall conform to NSF 184 ...
Section P2717 Plumbing Fixtures, Dishwashing Machines
The water supply to a dishwasher shall be protected against backflow by an air gap complying with ASME A112.1.3 or A112.1.2 that is installed ...
Section P2717 Plumbing Fixtures, Dishwashing Machines
The water supply to a dishwasher shall be protected against backflow by an air gap complying with ASME A112.1.3 or A112.1.2 that is installed ...
802.1.6 Indirect/Special Waste, Commercial Dishwashing Machines
The discharge from a commercial dishwashing machine shall be through an air gap or air break into a waste receptor in accordance with Section 802.3 ...
802.1.8 Indirect/Special Waste, Domestic Dishwashing Machines
Domestic dishwashing machines may be connected to a separately trapped stand pipe provided with an air break (with drain hose secured ...