603.7 Discontinuing Operation of Unsafe Heating Appliances
JUMP TO FULL CODE CHAPTER
The fire code official is authorized to order that measures be taken to prevent the operation of any existing stove, oven, furnace, incinerator, boiler or any other heat-producing device or appliance found to be defective or in violation of code requirements for existing appliances after giving notice to this effect to any person, owner, firm or agent or operator in charge of the same. The fire code official is authorized to take measures to prevent the operation of any device or appliance without notice when inspection shows the existence of an immediate fire hazard or when imperiling human life. The defective device shall remain withdrawn from service until all necessary repairs or alterations have been made.
Note: The fire code official may request a copy of the latest certificate of inspection from the Virginia Department of Labor and Industry for boilers and pressure vessels subject to such requirements. When the certificate is not available, the fire code official shall notify the Department of Labor and Industry to ensure that the required maintenance and testing is performed in accordance the Virginia Boiler and Pressure Vessel Regulations (16VAC25-50).
It shall be a violation of this code for any person, user, firm or agent to continue the utilization of any device or appliance (the operation of which has been discontinued or ordered discontinued in accordance with Section 603.7) unless written authority to resume operation is given by the fire code official. Removing or breaking the means by which operation of the device is prevented shall be a violation of this code.
Related Code Sections
603.7 Building Services and Systems, Discontinuing Operation of Unsafe Heating Appliances
, firm or agent to continue the utilization of any device or appliance (the operation of which has been discontinued or ordered discontinued ...
2012 Virginia Statewide Fire Prevention Code > 6 Building Services and Systems > 603 Fuel-Fired Appliances > 603.7 Discontinuing Operation of Unsafe Heating Appliances
603.7.1 Building Services and Systems, Unauthorized Operation
It shall be a violation of this code for any person, user, firm or agent to continue the utilization of any device or appliance (the operation ...
2015 Virginia Statewide Fire Prevention Code > 6 Building Services and Systems > 603 Fuel-Fired Appliances > 603.7 Discontinuing Operation of Unsafe Heating Appliances > 603.7.1 Unauthorized Operation
Section 110 Administration, Unsafe Conditions
escapes, stairs, passageways, doors or windows, which are liable to interfere with the egress of occupants or the operation of the fire department in case ...
108.7 Scope and Administration, Unsafe Installations
An installation that is unsafe, constitutes a fire or health hazard, or is otherwise dangerous to human life, as regulated by this code, is hereby ...
2015 Virginia Fuel Gas Code > 1 Scope and Administration > 108 (IFGC) Violations > 108.7 Unsafe Installations
108.7 Scope and Administration, Unsafe Mechanical Systems
A mechanical system that is unsafe, constitutes a fire or health hazard, or is otherwise dangerous to human life, as regulated by this code ...
2015 Virginia Mechanical Code > 1 Scope and Administration > 108 Violations > 108.7 Unsafe Mechanical Systems