E4203.3 Disconnecting Means
JUMP TO FULL CODE CHAPTER
One or more means to
simultaneously disconnect all ungrounded conductors for all
utilization equipment, other than lighting, shall be provided.
Each of such means shall be readily accessible and within
sight from the equipment it serves and shall be located at least
5 feet (1524 mm) horizontally from the inside walls of a pool,
spa, or hot tub unless separated from the open water by a permanently
installed barrier that provides a 5-foot (1524 mm)
or greater reach path. This horizontal distance shall be measured
from the water's edge along the shortest path required
to reach the disconnect. (680.12)
Related Code Sections
E3701.5.1 Branch Circuit and Feeder Requirements, Disconnecting Means
Each multiwire branch
circuit shall be provided with a means that will simultaneously
disconnect all ungrounded conductors at the point
where ...
2015 Michigan Residential Code > 37 Branch Circuit and Feeder Requirements > E3701 General > E3701.5 Multiwire Branch Circuits > E3701.5.1 Disconnecting Means
E4101.5 Appliance Installation, Disconnecting Means
Each appliance shall be provided with a means to disconnect all ungrounded supply conductors. For fixed electric space-heating equipment, means shall ...
2015 Michigan Residential Code > 41 Appliance Installation > E4101 General > E4101.5 Disconnecting Means
E4203.3 Swimming Pools, Disconnecting Means
One or more means to
simultaneously disconnect all ungrounded conductors for all
utilization equipment, other than lighting, shall be provided.
Each ...
2015 Michigan Residential Code > 42 Swimming Pools > E4203 Equipment Location and Clearances > E4203.3 Disconnecting Means
E4207.6 Swimming Pools, Disconnecting Means
Disconnecting means for
storable pools and storable/portable spas and hot tubs shall
comply with Section E4203.3 ...
2015 Michigan Residential Code > 42 Swimming Pools > E4207 Storable Swimming Pools, Storable Spas, and Storable Hot Tubs > E4207.6 Disconnecting Means
E3404.13 General Requirements, Identification of Disconnecting Means
Each disconnecting
means shall be legibly marked to indicate its purpose,
except where located and arranged so that the purpose
is evident. The ...
2015 Michigan Residential Code > 34 General Requirements > E3404 General Equipment Requirements > E3404.13 Identification of Disconnecting Means