P-1202.3 Discharge of Clear Water Wastes
Go To Full Code Chapter
Water lifts, expansion tanks, cooling jackets, drip or over-flow pans, or
similar devices which waste clear water only, shall discharge onto a roof, into a sump, or drain into a trapped fixture
or receptacle. Drains from sprinkler systems shall be discharged onto a roof, into a sump, or drain into a trapped
fixture or receptacle. Drains from sprinkler systems shall be discharged onto a roof, into a sump or over an open
trapped outlet of sufficient size to permit maximum flow from the drain under full system pressure without
overflowing.
Related Code Sections
P-1202.3 Indirect and Special Waste, Discharge of Clear Water Wastes
Water lifts, expansion tanks, cooling jackets, drip or over-flow pans, or
similar devices which waste clear water only, shall discharge onto a roof ...
Section 802 Indirect/Special Waste, Indirect Wastes
Food-handling equipment, in other than dwelling units, clear-water waste, humidifiers, dishwashing machines and utensils, pots, pans and dishwashing ...
709.4 Sanitary Drainage, Values for Indirect Waste Receptor
receptors such as floor drains, floor sinks and hub drains receive only clear-water waste from display cases, refrigerated display cases, ice bins, coolers ...
P-1201.1 Indirect and Special Waste, Required for Discharge
Indirect waste shall be required for the discharge of all waste from:
Any refrigerator, ice-box, steam table, bar or soda fountain, swimming pool ...
802.4 Indirect/Special Waste, Waste Receptors
For other than hub drains that receive only clear-water waste and standpipes, a removable strainer or basket shall cover the outlet of waste ...