R403.5.6.1.2 Directly Ducted and Individual Room Inlets
JUMP TO FULL CODE CHAPTER
When outdoor air is supplied directly to habitable spaces with an airflow of 20 cfm (0.57 m3/m) or greater, the system shall be designed and installed to temper incoming air to not less than 40°F (4°C) measured at the point of distribution into the space.
Related Code Sections
R403.5.6.1.2 [RE] Residential Energy Efficiency, Directly Ducted and Individual Room Inlets
When outdoor air is supplied directly to habitable spaces with an airflow of 20 cfm (566 L/min) or greater, the system shall be designed ...
2020 Minnesota Energy Code > 4 [RE] Residential Energy Efficiency > R403 Systems > R403.5 Mechanical Ventilation (Mandatory) > R403.5.6 Installation Requirements > R403.5.6.1 Air Distribution/Circulation > R403.5.6.1.2 Directly Ducted and Individual Room Inlets
R403.5.6.1.2 [RE] Residential Energy Efficiency, Directly Ducted and Individual Room Inlets
When outdoor air is supplied directly to habitable spaces with an airflow of 20 cfm (0.57 m 3 /m) or greater, the system shall be designed ...
Minnesota Energy Code 2015 > 4 [RE] Residential Energy Efficiency > R403 Systems > R403.5 Mechanical Ventilation (Mandatory) > R403.5.6 Installation Requirements > R403.5.6.1 Air Distribution/Circulation > R403.5.6.1.2 Directly Ducted and Individual Room Inlets
409.3 Special Detailed Requirements Based on Use and Occupancy, Projection Room and Equipment Ventilation
air throughout the room. Air inlet ducts shall provide an amount of air equivalent to the amount of air being exhausted by projection equipment. Air ...
Minnesota Building Code 2015 > 4 Special Detailed Requirements Based on Use and Occupancy > 409 Motion Picture Projection Rooms > 409.3 Projection Room and Equipment Ventilation
409.3 Special Detailed Requirements Based on Occupancy and Use, Projection Room and Equipment Ventilation
air throughout the room. Air inlet ducts shall provide an amount of air equivalent to the amount of air being exhausted by projection equipment. Air ...
2020 Minnesota Building Code > 4 Special Detailed Requirements Based on Occupancy and Use > 409 Motion Picture Projection Rooms > 409.3 Projection Room and Equipment Ventilation
R403.5.6.1 [RE] Residential Energy Efficiency, Air Distribution/Circulation
Outdoor air shall be delivered to each habitable space by a forced air circulation system, separate duct system, or individual inlets ...
2020 Minnesota Energy Code > 4 [RE] Residential Energy Efficiency > R403 Systems > R403.5 Mechanical Ventilation (Mandatory) > R403.5.6 Installation Requirements > R403.5.6.1 Air Distribution/Circulation