1024.2.8 Directional Signage at Transfer Levels and Where Egress Direction Is Not Clear
JUMP TO FULL CODE CHAPTER
Luminous directional signs designed in compliance with Section 1024.6.1 and installed at heights indicated in Section 1024.2.7 shall be placed on the wall at transfer levels and wherever egress direction is not clear; including at turns along horizontal extensions, at transitions from vertical to horizontal direction and at a "T" intersection. These directional signs shall include arrows indicating the direction of travel. The word "EXIT" shall not be required. Directional signs at transfer levels shall comply with Figure S101.1(9) in Appendix S.
Related Code Sections
1024.2.8 Means of Egress, Directional Signage at Transfer Levels and Where Egress Direction Is Not Clear
on the wall at transfer levels and wherever egress direction is not clear; including at turns along horizontal extensions, at transitions from vertical ...
NYC Building Code 2014 > 10 Means of Egress > 1024 Luminous Egress Path Markings > 1024.2 Required Markings > 1024.2.8 Directional Signage at Transfer Levels and Where Egress Direction Is Not Clear
1007.10 Means of Egress, Directional Signage
Direction signage indicating the location of the other means of egress and which are accessible means of egress shall be provided at the following ...
NYC Building Code 2014 > 10 Means of Egress > 1007 Accessible Means of Egress > 1007.10 Directional Signage
*1110.2 Accessibility, Directional Signage
Directional signage indicating the route to the nearest like accessible element shall be provided at or in close proximity to the following locations ...
1110.2 Accessibility, Directional Signage
Directional signage indicating the route to the nearest like accessible element shall be provided at or in close proximity to the following locations ...
Section 1026 Means of Egress, Signage
, horizontal exits, and exit passageways Exception: Within street level lobbies where egress direction is immediately discernable ...