Side-hinged swinging doors, pivoted doors and balanced doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 or more persons or a Group H occupancy.
Upcodes Diagrams

Related Code Sections

1010.1.2.1 Means of Egress, Direction of Swing
Pivot or side-hinged swinging doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 ...
1010.1.2.1 Means of Egress, Direction of Swing
Side-hinged swinging doors, pivoted doors and balanced doors shall swing in the direction of egress travel where serving a room or area ...
1204.7 Historic Buildings, Door Swing
Where approved by the code official, existing front doors need not swing in the direction of exit travel, provided that other approved exits having ...